QUICK START GUIDE Cisco ASR 1006 Router 1 Documentation and Resources 2 Prepare for Installation 3 Rack-Mount the Router 4 Connect the Router to the Network 5 Start the System 6 Configure the Router 7 After Installation
1 Documentation and Resources Documentation for the Cisco ASR 1000 Series Aggregation Services Routers documentation is online with the exception of the regulatory compliance and safety documentation and the Cisco ASR 1000 Series Aggregation Services Routers documentation flyer. Refer to the following documentation for installation and replacement of parts (including shared port adapters) and regulatory compliance information.
2 Prepare for Installation This section contains information about tools and parts, warnings, site preparation information, and information for rack-mount installation and equipment shelf or tabletop installation. Warning Only trained and qualified personnel should install, replace, or service this equipment. Statement 1030 Before beginning this router installation, read the Regulatory Compliance and Safety Information for the Cisco ASR 1000 Series Aggregation Services Routers document.
Prepare for Rack-Mount Installation Before you begin the rack-mounting tasks: • Decide whether or not you want to front rack-mount or rear rack-mount the chassis • Decide whether or not you want to attach cable-management brackets to your chassis. Note If you install cable-management brackets, make certain that the chassis is installed in the equipment rack first. • Decide if a two-post or four-post rack-mount will be used.
Step 4 Figure 2 Insert and tighten the black screws on one side.
Figure 3 Cisco ASR 1006 Router Rear Rack-Mounting 1 2 1 3 1 280038 0 0 4 1 Rear rack-mount bracket attached to the chassis 3 Components that slide into the mounted bracket 2 Rear rack-mount bracket component 4 Rear rack-mount bracket screw Step 3 Insert and tighten the five screws. After the bracket is secured to the side of the chassis, slide the two remaining components (item 3, Figure 3) into the side rack-mount bracket.
Figure 4 Installing the Cisco ASR 1006 Router in a Four-Post Rack 1 A A A C/ L C/ A/ 1 C/ A/ L C/ A/ 2 A L C/ A/ 0 3 A L C/ A/ 1 L A/ A/ 0 00 C/ A/ 1 C/ A/ L C/ A/ C/ A/ 3 L C/ A/ L PWR F1 STAT F0 STAT A A/ C/ A/ L C/ A/ A/ L C/ A/ L C/ A/ A L SPA-4XOC3-POS C/ A/ 3 A L C/ A/ 1 ASR1000-SIP10 L L C/ A/ L C/ A/ L C/ A/ C/ A/ L C/ A/ 0 STBY 1 A L C/ A/ 2 A PWR STATUS L A 1 ACTV A SPA-4XOC3-POS A 0 SPA-4XOC3-POS L SPA-4XOC3-POS
Step 7 Align the mounting bracket holes with the rack post holes and attach the chassis to the rack. At this point, if there is a third person, then that person can insert the screws while the other two people hold that chassis in place, unless the chassis is resting on a shelf). Step 8 Position the chassis until the rack-mounting ears are flush against the mounting rails on the rack. Step 9 Hold the chassis in position against the mounting rails and follow these steps: a.
Installing the Cisco ASR 1006 Router in a Two-Post Rack A A A C/ A/ A/ 11 L C/ A/ 1 C/ A/ L C/ A/ 0 L C/ A/ 3 A L C/ A/ 1 L A/ C/ A/ 00 C/ A/ 1 C/ A/ L C/ A/ C/ A/ 3 L C/ A/ L A/ PWR F0 STAT 6 A C/ L C/ A/ A/ L A/ L C/ A/ A L L A/ C/ A/ L C/ A/ L C/ A/ A/ ACTV L C/ A/ L C/ A/ STBY 1 A L C/ A/ 2 0 L A A PWR STATUS A SPA-4XOC3-POS A 1 C/ L SPA-4XOC3-POS 3 A/ 0 SPA-4XOC3-POS 2 A A 2 C/ L L SPA-4XOC3-POS C/ 3 A 1 ASR1000-SIP
Note As a result of using the specified rack-mount bracket ear holes, the cable-management bracket can be easily attached to the rack-mount bracket when the chassis is in the rack. This completes the procedure for installing the chassis in a two-post rack. Proceed to the “Attach the Cable-Management Bracket” section on page 10 to continue the installation.
Figure 6 Attaching the Cable-Management Bracket to the Cisco ASR 1006 Router A C/ A/L A C/ A/L C/ A -POS SPA-4XOC3 A C/ A/L C/ A A/L A C/ 1 2 3 A/L A C/ A/L -POS SPA-4XOC3 C/ A 3 C/ 3 C/ A ST AT US A/L A C/ A/L A C/ -POS SPA-4XOC3 A C/ C/ A/L A C/ A/L A 1 -POS SPA-4XOC3 1 2 3 A/L ST AT US 2 3 A/L A C/ A/L 0 A C/ A/L A C/ ST AT US A/L A C/ ST AT US A/L 0 3 A C/ A/L ST AT C/ A/L A C/ A/L 2 1 A US C/ ST AT A/L 3 A C/ A/L A C/ A/L -POS SPA-4XOC3 2 A
Chassis Ground Connection Installation Before you connect power or turn on power to your router, you must provide an adequate chassis ground (earth) connection for the router chassis. A ground connector is provided on each Cisco ASR 1006 Router. See Figure 7. Caution The dual-lug chassis stud must be installed, the SIP and SPA must be fully inserted and screwed in and earthed to prevent a potential hazard in a telecom line.
Step 8 Connect the opposite end of the grounding wire to the appropriate grounding point at your site to ensure an adequate chassis ground. This completes the procedure for attaching a chassis ground connection. Go to the “Connect the Router to the Network” section on page 13 for information on attaching cables. 4 Connect the Router to the Network This section provides information about cables and ports and attaching the router to the network.
– Connect to the port using the RJ-45-to-RJ-45 cable and RJ-45-to-DB-25 DTE adapter or using the RJ-45-to-DB-9 DTE adapter.
Install the Cables in the Cable-Management Bracket No specific card level cable-management will be provided on the SIP carrier cards. SPAs utilize the SPA cable-management brackets that are provided with each SPA as part of their accessory kits. Cables coming off the front side of the SPAs and SIPs utilize the chassis level cable-management brackets provided on the chassis rack mount brackets (see Figure 8).
Step 2 Plug the power cable into the inlet. Note For additional AC power cable strain relief, secure the cable to the power supply handle by inserting a nylon cable tie through the hole in the handle and around the cable. Figure 10 Cisco ASR 1006 Series Router AC Power Supply 6 7 8 OUTPUT INPUT INPUT FAIL OK OK ALARMS 60V 1A MAX 100-240V~ 16-7A 50-60HZ 5 280029 This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
DC input power cables must be connected to the PDU terminal studs in the proper positive (+) and negative (–) polarity. In some cases, the DC cable leads are labeled, which is a relatively safe indication of the polarity. However, you must verify the polarity by measuring the voltage between the DC cable leads. When making the measurement, the positive (+) lead and the negative (–) lead must always match the (+) and (–) labels on the power distribution unit.
Figure 13 DC Power Supply Ground Studs and Cables 1 2 OFF -48/-60V 40A This unit might have more than one power supply connection.
Figure 14 DC Power Supply Terminal Block 1 2 OFF 55 -48/-60V ht have m 4 ore than on e power su pply conn ection. Al l connectio ns must be remov 280027 This unit mig 40A 3 1 DC power supply terminal block negative stud 3 Terminal block slotted keyed area 2 DC power supply terminal block positive stud 4 DC power supply terminal block plastic cover Caution Step 3 20 Before you continue to install the terminal block ground wires, stop and perform Step 5.
Figure 15 DC Power Supply Terminal Block Positive and Negative Cable Lugs With Protective Sleeving 1 2 OFF -48/-60V 40A This unit might have more than one power supply connection.
DC Power Supply Terminal Block Positive and Negative Connections 280311 Figure 16 Step 5 Tighten the Kepnut screw to recommended torque of 18 in-lbs minimum to 22 in-lbs maximum for the positive stud and wire. Note Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact. Step 6 Use tie wraps to secure the wires, so that the wires are not pulled from the terminal block by casual contact.
Figure 17 DC Power Supply Terminal Block and Plastic Cover 1 2 OFF 55 -48/-60V ht have m ore than on e power su pply conn ection. Al 4 l connectio ns must be remov 280027 This unit mig 40A 3 1 Negative lead 3 Plastic cover slotted area 2 Positive lead 4 Terminal block plastic cover Caution Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact. There are tabs located on the base of the DC power supply to which to secure the ties.
Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco ASR1006 router. The other Cisco ASR1000 routers display similar type of output.
LED Label LED Color In the Power Up State -Behavior Description STAT System status Solid green Cisco IOS has successfully booted. Yellow BOOT ROM has successfully loaded. Red System failure. ACTV Active Green Lit when this is the active ASR 1000 Series RP1. STBY Standby Yellow Lit when this is the standby ASR 1000 Series RP1. CRIT Critical Solid red Critical alarm indicator. This is on at power up, turned off by software. MAJ Major Solid red Major alarm indicator.
validate_package: SHA-1 hash: calculated 479a7d62:6c128ba8:3616b8da:93cb3224:5c1aeb34 expected 479a7d62:6c128ba8:3616b8da:93cb3224:5c1aeb34 Image validated PPC/IOS XE loader version: 0.0.3 loaded at: 00800000 0D1E2004 zimage at: 00807673 009B8C69 initrd at: 009B9000 01006219 isord at: 01007000 0D1DF800 avail ram: 00400000 00800000 Kernel load: Uncompressing image... dst: 00000000 lim: 00400000 start: 00807673 size: 001B15F6...done.
*Feb 19 17:34:27.361: % Error opening nvram:/ifIndex-table No such file or directory *Feb 19 17:34:28.235: %ASR1000_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-intf created with ID 4085, ipv4 table-id 0xFF5, ipv6 table-id 0x1E000001 *Feb 19 17:34:29.720: %PARSER-4-BADCFG: Unexpected end of configuration file. *Feb 19 17:34:29.809: %NETCLK-5-NETCLK_MODE_CHANGE: Network clock source not available. The network clock has changed to freerun *Feb 19 17:34:10.
TFTP_SERVER: 172.27.55.254 TFTP_FILE: asr1000rp1-advipservicesk9.v122_33_xn_asr_rls0_throttle_20080114_045627.bin Using midplane macaddr TFTP_MACADDR: 00:1a:30:44:34:ff TFTP_VERBOSE: Progress TFTP_RETRY_COUNT: 18 TFTP_TIMEOUT: 7200 TFTP_CHECKSUM: Yes ETHER_PORT: 3 ETHER_SPEED_MODE: Auto Detect link up 1000Mbps/FD. Receiving asr1000rp1-advipservicesk9.v122_33_xn_asr_rls0_throttle_20080114_045627.bin from 172.27.55.
Cisco IOS Software, IOS-XE Software (PPC_LINUX_IOSD-ADVIPSERVICESK9-M), Experimental Version 12.2(20080110:152728) [BLD-mcp_dev.MCP_CRYPTO_INCREMENTAL_BLD_20080110 103] Copyright (c) 1986-2008 by Cisco Systems, Inc. Compiled Thu 10-Jan-08 07:29 by mcpre Image text-base: 0x10062810, data-base: 0x132AF1F8 This product contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use.
Cisco IOS Software, IOS-XE Software (PPC_LINUX_IOSD-ADVIPSERVICESK9-M), Experimental Version 12.2(20080110:152728) [BLD-mcp_dev.MCP_CRYPTO_INCREMENTAL_BLD_20080110 103] Copyright (c) 1986-2008 by Cisco Systems, Inc. Compiled Thu 10-Jan-08 07:29 by mcpre *Feb 13 12:49:01.253: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF Router> During the boot process, observe the system LEDs. The LEDs on the shared port adapter go on and off in irregular sequence. They may go on, go out, and go on again for a short time.
Default settings are in square brackets '[]'. Basic management setup configures only enough connectivity for management of the system, extended setup will ask you to configure each interface on the system. --- System Configuration Dialog --Would you like to enter the initial configuration dialog? [yes/no]: y At any point you may enter a question mark '?' for help. Use ctrl-c to abort configuration dialog at any prompt. Default settings are in square brackets '[]'.
hostname Router enable secret 5 $1$6r./$U5wHcV3uRWkKWK/fap474.
! interface GigabitEthernet0 shutdown no ip address dialer-list 1 protocol ip permit dialer-list 1 protocol ipx permit ! end [0] Go to the IOS command prompt without saving this config. [1] Return back to the setup without saving this config. [2] Save this configuration to nvram and exit. Enter your selection [2]: Router#reload Proceed with reload? [confirm] *Jan 11 06:59:29.476: %SYS-5-RELOAD: Reload requested by console. Reload Reason: Reload command. System Bootstrap, Version 12.
PPC/IOS XE loader version: 0.0.3 loaded at: 00800000 0CD2C004 zimage at: 00807673 009B8E53 initrd at: 009B9000 01006E53 isord at: 01007000 0CD2A000 avail ram: 00400000 00800000 Kernel load: Uncompressing image... dst: 00000000 lim: 00400000 start: 00807673 size: 001B17E0...done. Now booting the IOS XE kernel %IOSXEBOOT-4-BOOT_PARAMETER: (rp/0): Booting with custom BOOT_PARAM setting %IOSXEBOOT-4-DEBUG_CONF: (rp/0): File /misc/scratch/debug.
Note Basic management setup configures enough connectivity for managing the system; extended setup will ask you to configure each interface on the system. For detailed information about setting global parameters, refer to the Cisco ASR 1000_Series Aggregation Services Routers Software Configuration Guide.
7 After Installation Follow the instructions in this section to replace field replaceable units (FRUs) after installation.
Replace a Power Supply in a Cisco ASR 1006 Router This section provides instructions for removing and replacing the AC power supply and the DC power supply in a Cisco ASR 1006 Router. Before you begin, make certain the chassis is grounded.
The second is after enabling console logging. Output is at the console (and in the log). 6ru_perf2#conf Configuring from terminal, memory, or network [terminal]? Enter configuration commands, one per line. End with CNTL/Z. 6ru_perf2(config)#log con % Ambiguous command: "log con" 6ru_perf2(config)#logg con 6ru_perf2(config)#^Z 6ru_perf2# *Jan 10 06:08:54.643: %SYS-5-CONFIG_I: Configured from console by console 6ru_perf2# 6ru_perf2# *Jan 10 06:09:05.
Figure 18 DC Power Supply Terminal Block 1 2 OFF 55 -48/-60V ore than on 4 e power su pply conn ection. Al l connectio ns must be remov 280027 This unit might have m 40A 3 1 DC power supply terminal block negative lead stud 3 Plastic cover sloted and keyed area 2 DC power supply positive lead stud 4 DC power supply terminal block plastic cover Step 6 Locate the power supply ground stud. Remove the earth ground (GND) cable from the power supply.
Console logging: disabled Monitor logging: level debugging, 0 messages logged, xml disabled, filtering disabled Buffer logging: level debugging, 81 messages logged, xml disabled, filtering disabled Exception Logging: size (4096 bytes) Count and timestamp logging messages: disabled Persistent logging: disabled No active filter modules. Trap logging: level informational, 78 message lines logged Log Buffer (10000000 bytes): *Jan 10 06:08:14.
Figure 19 Handling a SPA 70006 Printed circuit board Metal carrier GND To install a shared port adpter into a SPA interface processor (SIP), follow these steps: Step 1 Before you begin, make certain the chassis is grounded. Step 2 To insert the SPA in the SIP, locate the guide rails inside the SIP that hold the SPA in place. They are at the top left and top right of the SPA slot and are recessed about an inch.
Step 4 After the SPA is properly seated, fasten the SPA in place with the captive installation screws on either side of the SPA. Note The shared port adapter ships installed. These instructions are provided for future use. Cabling information is included with the specific shared port adapter documentation. Step 1 Attach an ESD wrist strap between you and an unpainted chassis surface. Step 2 If attached, remove any cables from the SPA.
Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Asia Pacific Headquarters Cisco Systems, Inc. 168 Robinson Road #28-01 Capital Tower Singapore 068912 www.cisco.com Tel: +65 6317 7777 Fax: +65 6317 7799 Europe Headquarters Cisco Systems International BV Haarlerbergpark Haarlerbergweg 13-19 1101 CH Amsterdam The Netherlands www-europe.cisco.