Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note Product numbers: WS-F6700-DFC3A(=), WS-F6700-DFC3B(=), WS-F6700-DFC3BXL(=) This publication contains the procedures for installing the Distributed Forwarding Card 3 (DFC3) on Ethernet modules.
Contents Contents This publication contains these sections: • Installation Requirements and Guidelines, page 2 • Safety Overview, page 3 • Required Tools and Parts, page 9 • Removing a CFC or DFC Daughter Card, page 10 • Removing the DFC3 Daughter Card, page 12 • Upgrading the DFC3BXL Daughter Card Memory, page 19 • Installing the DFC3 Daughter Card, page 23 • Removing and Installing Modules in the Chassis, page 32 • Attaching Your ESD Grounding Strap, page 40 • Related Documentation, pa
Safety Overview Table 1 PFC3/DFC3 Operating Restrictions PFC Version DFC Version Restrictions PFC3A DFC3A No restrictions. DFC3B The DFC3B functions as a DFC3A. DFC3BXL The DFC3BXL functions as a DFC3A. DFC3A You must reset the system after installing a DFC3A-equipped module. PFC3B The PFC3B functions as a PFC3A. PFC3BXL DFC3B No restrictions. DFC3BXL The DFC3BXL functions as a DFC3B. DFC3A You must reset the system after installing a DFC3A-equipped module.
Safety Overview Statement 1071—Warning Definition Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device.
Safety Overview Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
Safety Overview Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.
Safety Overview Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo.
Safety Overview Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note 8 78-15893-06
Required Tools and Parts Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing.
Removing a CFC or DFC Daughter Card These tools and supplies are required to remove and install the DFC3 daughter card: • Antistatic mat or foam pad to support the removed module and an antistatic bag to store the removed Central Forwarding Card (CFC) or DFC daughter card • Your own ESD-prevention equipment or the disposable grounding wrist strap included in the upgrade kit • Number 1 Phillips-head screwdriver for the DFC daughter card installation hardware Removing a CFC or DFC Daughter Card If your
Removing a CFC or DFC Daughter Card Figure 1 CFC Daughter Card Securing Screws and Cap Nuts Cap nuts (2) Card removal tabs (2) CFC daughter card Heat sinks Screws (3) WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99714 WS-X5530 Step 5 To unseat the CFC daughter card from the Ethernet module, hold each tab at the rear of the CFC daughter card between your thumb and index finger, and gently press down on both
Removing the DFC3 Daughter Card Figure 2 Unseating the CFC Daughter Card Connectors Heat sinks WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP 120046 WS-X5530 STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 Step 6 Gently lift the CFC daughter card with both hands and remove the CFC daughter card from the module. Step 7 Place the CFC daughter card on an antistatic mat, antistatic foam pad, or in an antistatic bag.
Removing the DFC3 Daughter Card Removing the DFC3 Daughter Card from Modules Without Stiffener Brackets To remove the DFC3 daughter card from modules that are not equipped with a stiffener bracket, follow these steps: Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 Step 1 Attach an ESD grounding strap to your wrist and to ground.
Removing the DFC3 Daughter Card Step 6 Partially reinstall the cap nut, as shown in Figure 4, about 3 turns so that there is a space of about 1/8 inch (3 mm) between the bottom of the cap nut and the top of the DFC3 daughter card. The cap nut acts as a stop when you unseat the daughter card connector so that the DFC3 daughter card does not move horizontally and cause damage to the base board.
Removing the DFC3 Daughter Card Figure 5 Unseat the DFC3 Daughter Card from the Module Lift here Rock up and down WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 120048 WS-X5530 Step 8 Remove the one cap nut. Step 9 Holding the DFC3 daughter card with both hands, gently lift it straight up from the module. (See Figure 6.
Removing the DFC3 Daughter Card Figure 6 Removing the DFC3 Daughter Card from the Module Unseat the DFC power connector Lift here Lift here WS-X5530 WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 Removing the DFC3 Daughter Card from Modules Equipped with a Stiffener Bracket Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card.
Removing the DFC3 Daughter Card To remove a DFC3 daughter card from a WS-X6748-GE-TX Ethernet module equipped with a stiffener bracket, follow these steps: Step 1 Attach an ESD grounding strap to your wrist and to ground. (If you are unsure about the correct way to attach an ESD grounding strap, refer to the “Attaching Your ESD Grounding Strap” section on page 40 for instructions.) Step 2 Remove the WS-X6748-GE-TX Ethernet module from the Catalyst 6500 series switch.
Removing the DFC3 Daughter Card Note Step 6 The two screws securing the DFC3 daughter card that pass through the front stiffener bracket tabs are longer than the remaining DFC installation screws. With your left hand, lift slightly at the location shown in Figure 8, and gently rock the DFC3 daughter card up and down to unseat the daughter card from the module connectors.
Upgrading the DFC3BXL Daughter Card Memory Figure 9 Removing the DFC3 Daughter Card (WS-X6748-GE-TX Equipped with a Front Stiffener Bracket) Lift here to unseat DFC power connector Stiffener bracket WS-X6748-GE-TX 48 PORT ETHERNET 130151 WS-X5530 Stiffener bracket tabs Upgrading the DFC3BXL Daughter Card Memory Upgrading your module with a DFC3BXL daughter card requires that you also install a 1-GB memory upgrade (part number MEM-XCEF720-1GB) that comes with your DFC3BXL upgrade kit.
Upgrading the DFC3BXL Daughter Card Memory Removing the SODIMM Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 To remove the existing SODIMM, follow these steps: Step 1 Attach an ESD grounding strap to your wrist and to ground.
Upgrading the DFC3BXL Daughter Card Memory Step 3 Release the spring clips from the SODIMM, and release the SODIMM from the socket. (See Figure 11.) Figure 11 Releasing the SODIMM Spring Clips Pull the tabs away with your thumbs, bracing your forefingers against the rails. The memory module will be released. Then raise the memory module to a vertical position.
Upgrading the DFC3BXL Daughter Card Memory Handling a SODIMM 51544 Figure 12 Step 5 Immediately place the old SODIMM in an antistatic bag to protect it from ESD damage. Installing the SODIMM Caution SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM). (See Figure 12.
Installing the DFC3 Daughter Card Installing the SODIMM 28736 Figure 13 Step 6 When the SODIMM is installed, check the two alignment holes, and ensure that the spring retainer is visible. If it is not, the SODIMM is not seated properly. If any SODIMM appears misaligned, carefully remove it and reseat it in the socket. Push the SODIMM firmly back into the socket until the retainer springs snap into place. Installing the DFC3 Daughter Card This section contains two DFC3 installation procedures.
Installing the DFC3 Daughter Card Figure 14 Mounting Holes on the DFC3 Daughter Card 99361 99361 Align with the male standoffs on the module Figure 15 Male Standoff Locations on the WS-X67xx Modules Male standoffs WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99716 WS-X5530 Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note 24 78-15893-06
Installing the DFC3 Daughter Card Step 4 Ensure that the connectors on the DFC3 are aligned with the connectors on the module. Figure 16 shows the connectors on the underside of the DFC3. Figure 16 DFC3 Daughter Card Connectors (Underside of DFC Daughter Card Shown) 99363 Connectors Step 5 Apply pressure to the area shown in Figure 17 to seat the power connector.
Installing the DFC3 Daughter Card Caution Use care not to damage the connectors on the module. If you damage a connector, it will be necessary to return the module to Cisco for repair. Step 6 Position the installation bracket over the two male standoffs at the back of the DFC daughter card. Apply pressure to the top of the bracket, as shown in Figure 18 to fully seat the DFC3 daughter card on the module.
Installing the DFC3 Daughter Card You should visually verify that there are standoffs beneath the mounting holes before installing the securing screws. Figure 19 Installing the Securing Screws and Cap Nuts WS-X5530 WS-X6724-SFP 24PORT GIGABIT ETHERNET - SFP STATUS 1 Step 8 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 71 18 19 20 21 22 23 24 99719 Note Reinstall the Ethernet module in the chassis.
Installing the DFC3 Daughter Card Installing the DFC3 Daughter Card on Modules Equipped with a Stiffener Bracket Note Some early versions of the WS-X6748-GE-TX Ethernet modules have a stiffener bracket mounted across the top front part of the module, which requires a modified procedure to install the DFC daughter card. Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card.
Installing the DFC3 Daughter Card Figure 20 Seating the DFC Daughter Card Power Connector (WS-X6748-GE-TX Equipped with a Front Stiffener Bracket) Apply pressure to seat DFC daughter card power connector Stiffener bracket WS-X6748-GE-TX 48 PORT ETHERNET 130152 WS-X5530 Stiffener bracket tabs. DFC daughter card slides underneath tabs.
Installing the DFC3 Daughter Card Step 7 Position the installation bracket over the two standoffs and press down on the top of the bracket to seat the DFC3 daughter card connectors on the module connectors. (See Figure 21.) Caution When seating the DFC3 daughter card on the module connectors, DO NOT touch or apply any pressure to the heat sinks. Press down on the installation bracket only.
Installing the DFC3 Daughter Card Figure 22 Installing the Screws and Cap Nuts (WS-X6748-GE-TX Equipped with a Front Stiffener Bracket) Installation bracket Stiffener bracket WS-X6748-GE-TX 48 PORT ETHERNET 154457 WS-X5530 Stiffener bracket tabs. DFC daughter card must be installed underneath tabs. Caution Step 10 You must install screws in all available standoffs. The screws provide grounding between the DFC3 daughter card and the module.
Removing and Installing Modules in the Chassis Removing and Installing Modules in the Chassis This section describes how to correctly remove and install a module in a Catalyst 6500 series switch chassis slot. Caution Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments.
Removing and Installing Modules in the Chassis Step 5 Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the following two sets of substeps: Horizontal slots a. Place your thumbs on the left and right ejector levers, and simultaneously rotate the levers outward to unseat the module from the backplane connector. b. Grasp the front edge of the module and slide the module part of the way out of the slot.
Removing and Installing Modules in the Chassis Step 4 Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the following two sets of substeps: Horizontal slots Caution a. Position the module in the slot. (See Figure 23.) Make sure that you align the sides of the module carrier with the slot guides on each side of the slot. b.
Removing and Installing Modules in the Chassis Figure 23 Positioning the Module in a Horizontal Slot Chassis Insert module between slot guides EMI gasket 3 4 5 6 4 5 6 1 2 3 4 FAN STATUS 5 EMI gasket 154230 6 o o INPUT OK FAN OK OUTPUT FAIL INPUT OK FAN OK OUTPUT FAIL WS-X6748-GE-TX 48 PORT ETHERNET Ejector lever fully extended Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note 78-15893-06 35
Removing and Installing Modules in the Chassis Figure 24 Clearing the EMI Gasket in a Horizontal Slot Chassis 1 2 3 Press down 4 FAN STATUS 5 Press down WS-X6224 24 PORT 100FX 6 3 4 4 WS-X6748-GE -TX 48 PORT ETH 6 Figure 25 1 mm Gap between the module EMI gasket and the module above it ERNET 5 154231 5 6 Ejector Lever Closure in a Horizontal Slot Chassis 1 2 3 4 FAN STATUS 5 154232 6 Ejector levers flush with module faceplate Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Ins
Removing and Installing Modules in the Chassis Vertical slots Caution a. Position the module in the slot. (See Figure 26.) Make sure that you align the sides of the module carrier with the slot guides on the top and bottom of the slot. b. Carefully slide the module into the slot until the EMI gasket along the right edge of the module makes contact with the module in the slot adjacent to it and both ejector levers have closed to approximately 45 degrees with respect to the module faceplate.
Removing and Installing Modules in the Chassis Figure 26 Positioning the Module in a Vertical Slot Chassis Ejector lever fully extended WS-X6748-GE-TX 48 PORT ETHERNET FAN STATUS EMI gasket EMI gasket o o INPUT OK FAN OK OUTPUT FAIL INPUT OK FAN OK OUTPUT FAIL 6 Insert module between slot guides 154233 3 4 Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note 38 78-15893-06
Removing and Installing Modules in the Chassis Figure 27 Clearing the EMI Gasket in a Vertical Slot Chassis Gap between the module EMI gasket and the module above it 1 mm WS-X6748-GE-TX 48 PORT ETHERNET FAN STATUS Press left 154234 Press left o o INPUT OK FAN OK OUTPUT FAIL INPUT OK FAN OK OUTPUT FAIL Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note 78-15893-06 39
Attaching Your ESD Grounding Strap Figure 28 Ejector Lever Closure in a Vertical Slot Chassis 154235 FAN STATUS All ejector levers flush with module faceplate Attaching Your ESD Grounding Strap Electrostatic discharge (ESD) damage, which can occur when modules or other FRUs are improperly handled, results in intermittent or complete failures. Modules consist of printed circuit boards that are fixed in metal carriers.
Attaching Your ESD Grounding Strap • If your chassis does not have the system ground attached, you must install the system ground lug. Refer to the online Catalyst 6500 Series Switches Installation Guide for the procedure.
Attaching Your ESD Grounding Strap Figure 29 Attaching the ESD Wrist Strap Clip to the System Ground Lug Screw Clip ESD ground strap Grounding lug Screw Side view of grounding lug Slide clip behind screw Clip installed behind screw System ground connector WS-X6K-SUP2-2GE T M LE G US O EM M T AT ST NS R SE ST SY CO PW RE Switch 100% CONSOLE PORT MODE CONSOLE SUPERVISOR2 Load PORT 1 PCMCIA PORT 2 EJECT OSM-4OC12 POS-SI NK LI NK LI 1 ST AT 3 AC TIV E RX 2 4 PORT OC-12 POS TX TX
Related Documentation Related Documentation These documents are available for the Catalyst 6500 series switches: • Regulatory Compliance and Safety Information for the Catalyst 6500 Series Switches • Catalyst 6500 Series Switch Installation Guide • Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide • Catalyst 6500 Series Switch Cisco IOS Command Reference • Catalyst 6500 Series DFC Memory Installation Note • Release Notes for Catalyst 6500 Series Switches Obtaining Documentation
Documentation Feedback Ordering Documentation Registered Cisco.com users may order Cisco documentation at the Product Documentation Store in the Cisco Marketplace at this URL: http://www.cisco.com/go/marketplace/ Nonregistered Cisco.com users can order technical documentation from 8:00 a.m. to 5:00 p.m. (0800 to 1700) PDT by calling 1 866 463-3487 in the United States and Canada, or elsewhere by calling 011 408 519-5055. You can also order documentation by e-mail at tech-doc-store-mkpl@external.cisco.
Obtaining Technical Assistance Reporting Security Problems in Cisco Products Cisco is committed to delivering secure products. We test our products internally before we release them, and we strive to correct all vulnerabilities quickly. If you think that you have identified a vulnerability in a Cisco product, contact PSIRT: • For Emergencies only — security-alert@cisco.
Obtaining Technical Assistance Cisco Technical Support & Documentation Website The Cisco Technical Support & Documentation website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day, at this URL: http://www.cisco.com/techsupport Access to all tools on the Cisco Technical Support & Documentation website requires a Cisco.com user ID and password.
Obtaining Additional Publications and Information Definitions of Service Request Severity To ensure that all service requests are reported in a standard format, Cisco has established severity definitions. Severity 1 (S1)—An existing network is down, or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Obtaining Additional Publications and Information • iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies learn how they can use technology to increase revenue, streamline their business, and expand services. The publication identifies the challenges facing these companies and the technologies to help solve them, using real-world case studies and business strategies to help readers make sound technology investment decisions.