Feature Cisco ASA 5505;
Security Plus
Cisco ASA 5510;
Security Plus
Cisco ASA 5512-X;
Security Plus
Cisco ASA 5515-X
4 GE SFP 6 GE SFP 6 GE SFP
Serial Ports 1 RJ-45 console 2 RJ-45, console and
auxiliary
1 RJ-45 console 1 RJ-45 console
Solid State Drive 1 slot, 120 GB MLC SED 1 slot, 120 GB MLC SED
Memory 512 MB 1 GB 4 GB 8 GB
Minimum System Flash 128 MB 256 MB 4 GB 8 GB
System Bus Multibus architecture Multibus architecture Multibus architecture Multibus architecture
Operating
Temperature 32 to 104°F (0 to 40°C) 32 to 104°F (0 to 40°C) 23 to 104°F (–5 to 4C) 23 to 104°F (–5 to 4C)
Relative Humidity 5 to 95 percent
noncondensing
5 to 95 percent
noncondensing
10 to 90 percent
noncondensing
10 to 90 percent
noncondensing
Altitude Designed and tested for 0
to 9840 ft (3000m); agency
approved for 2000m
Designed and tested for 0
to 9840 ft (3000m); agency
approved for 2000m
Designed and tested for 0
to 15,000 ft (4572m)
Designed and tested for 0
to 15,000 ft (4572m)
Shock 1.14 m/sec (45 in./sec) 1/2
sine input
1.14 m/sec (45 in./sec) 1/2
sine input
70G, 4.22 m/sec 70G, 4.22 m/sec
Vibration 0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
Acoustic Noise 60 dBa max 60 dBa max 64.2 dBa max 64.2 dBa max
Nonoperating
Temperature –13 to 158ºF (–25 to 70ºC) –13 to 158ºF (–25 to 70ºC) –13 to 158ºF (–25 to 70ºC) –13 to 158ºF (–25 to 70ºC)
Relative Humidity 5 to 95 percent
noncondensing
5 to 95 percent
noncondensing
10 to 90 percent
noncondensing
10 to 90 percent
noncondensing
Altitude 0 to 15,000 ft (4570m) 0 to 15,000 ft (4570m) Designed and tested for
0 to 15,000 ft (4570m)
Designed and tested for
0 to 15,000 ft (4570m)
Shock 30G 30G 70G, 4.22 m/sec 70G, 4.22 m/sec
Vibration 0.41 Grms2 (3 to 500 Hz)
random input
0.41 Grms2 (3 to 500 Hz)
random input
1.12 Grms2 (3 to 500 Hz)
random input
1.12 Grms2 (3 to 500 Hz)
random input
Power
Input (per Power Supply)
AC Range Line Voltage 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC
AC Normal Line Voltage 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC
AC Current 1.8A 3A 4.85A 4.85A
AC Frequency 50/60 Hz 47/63 Hz 50/60 Hz 50/60 Hz
Dual-Power Supplies None None None None
DC Domestic Line
Voltage
See the ASA 5500 Series
Hardware Installation Guide
See the ASA 5500 Series
Hardware Installation Guide
–40.5 to 56 VDC (–48 VDC
nominal)
–40.5 to 56 VDC (–48 VDC
nominal)
DC International Line
Voltage
See the ASA 5500 Series
Hardware Installation Guide
See the ASA 5500 Series
Hardware Installation Guide
–55 to –72 VDC
(–60 VDC nominal)
–55 to –72 VDC
(–60 VDC nominal)
DC Current See the ASA 5500 Series
Hardware Installation Guide
See the ASA 5500 Series
Hardware Installation Guide
15A (maximum input) 15A (maximum input)
Output
Steady State 20W 150W 51W 65W
Maximum Peak 96W 190W 56W 70W
Maximum Heat
Dissipation
72 BTU/hr 648 BTU/hr 192 BTU/hr 239 BTU/hr
Form Factor Desktop 1 RU, 19-in. rack-
mountable
1 RU, 19-in. rack-
mountable
1 RU, 19-in. rack-
mountable
Dimensions (H x W x D) 1.75 x 7.89 x 6.87 in.
(4.45 x 20.04 x 17.45 cm)
1.75 x 17.5 x 14.25 in. (4.45
x 20.04 x 36.20 cm)
1.67 x 16.7 x 15.6 In (4.24 x
42.9 x 39.5 cm)
1.67 x 16.7 x 15.6 In (4.24 x
42.9 x 39.5 cm)