Instruction Manual

FORM-ENG-0018 REV A 05-27-03
607 NW 27th Ave
Ocala, FL 34475
Ph: 352-629-5020 or 1-800-533-3569
Fax : 352-629-2902 or 1-800-520-3473
TECHNICAL DATA SHEET
PAGE
14 OF 26
DATE
3/28/2012
PRODUCT GROUP
THROTTLE CONTROL
P/N 117155 REV
1.23
PRODUCT
TOTAL PRESSURE GOVERNOR (TPG)
BY AMS
Manual P/N 117684
Menu items in menu levels 1, 2, and 3
MENU ITEM DESCRIPTION DEFAULT MENU LEVEL
UNITS
Configures units of measure
PSI / ºF
1
PRESET RPM
Configures the throttle mode (RPM) preset (900 1400)
(Not available with message type ANLG)
1000
1*
HI-IDLE
Configures the high idle RPM preset (900-1400)
(Not available with message type ANLG)
1100
1*
PRESET PSI
Configures the pressure mode (PSI) preset (90 130)
90
1
BRIGHT
Configures the display’s brightness level (1-15)
15
1
DISPLAY TEST
Tests all of the pixels of the main display
N/A
1
ROUND PSI
Configures the rounding of the pressure value
N
1
ALERT TONE
Alert tones are indicated by a double chirp of the alarm output and
do not indicate alarm conditions. Enable/disable the alert tones.
Y
2
SENSITIVITY
Configures the pressure sensitivity window (4 12)
+/- 6 PSI
2
-SENSOR CAL-
Calibrates the zero point of the pressure sensor
142 COUNTS
2
1ST MODE
Configures the first mode active when the MODE switch is pressed
(interlocks permitting)
PSI
2
AUTO MODE
Configures if governor automatically enters into psi mode upon
pump engagement.
(Only available when 1
st
mode menu item is set to PSI and menu level was 3 or greater)
NO
3*
COMM STATUS
Allows viewing of CAN messages per second and received errors
N/A
2
CONTROL
Configure control mode and message for engine
CFPG (Cummins)
3
RPM IDLE
Configure / adjust the idle rpm
(Not available with message type ANLG)
700
3*
RPM MAX
Configure / adjust the maximum rpm commanded by governor
(Not available with message type ANLG or CFPG)
2200
3*
SOURCE ID
Configure the CAN source ID for the TPG
(only available with message type PGN0 or SCAN)
7
3*
TSC1 RAMP
Configure the RPM ramp speed of TSC1/PGN0 control mode
(only available with message type PGN0)
0
3*
DISPLAY
Configure primary display while in pressure mode (rpm or pressure)
RPM
3
PSI TIME-OUT
Configures the amount of seconds the TPG will wait after pressure
has dropped below 30 PSI before dropping to IDLE mode
5
3
ALLOW PRESET
Configure enable/disable rpm preset if pump is under pressure
NO
3
WARNINGS
Configures source of the panel warning LED’s (data bus or user
defined)
Bus
3
WARN °F
Configure the yellow (warning) engine temp setpoint
(only available when WARNINGS is set to Usr)
-
3*
CRIT °F
Configure the red (critical) engine temp setpoint
(only available when WARNINGS is set to Usr)
-
3*
WARN PSI
Configure the yellow (warning) oil pressure setpoint
(only available when WARNINGS is set to Usr)
-
3*
CRIT PSI
Configure the red (critical) oil pressure setpoint
(only available when WARNINGS is set to Usr)
-
3*