TECHNICAL DATA SHEET
PAGE
18 OF 26
DATE
3/28/2012
PRODUCT GROUP
THROTTLE CONTROL
P/N 117155 REV
1.23
PRODUCT
TOTAL PRESSURE GOVERNOR (TPG)
BY AMS
Manual P/N 117684
5.2.15. RPMidle (idle RPM value)
This menu item allows configuration of the idle RPM.
The display will show RPMIdle=XXXX. Use the INC and DEC switches to adjust the RPM value desired for idle.
Note: cannot be adjusted below the engine’s curb idle speed.
Range = 650 RPM to 900 RPM (in 25 RPM steps). [default = 700 RPM]
5.2.16. RPMmaxi (maximum RPM value)
This menu item allows configuration of the maximum RPM that will be commanded when in PGN0 or SCANia
mode. The display will show RPMmaxi=XXXX. Use the INC and DEC switches to adjust the maximum RPM value
desired. This value cannot be adjusted above maximum governed speed.
Note: When control type is configured for Volvo (VLVO) or MAN the minimum value can be set down to
1500 RPM.
Range = 1900 RPM to 2500 RPM (in 25 RPM steps). [default = 2200 RPM]
5.2.17. SourceID (CAN message source identification)
This menu item allows configuration of the CAN source message ID number.
The display will show
SourceID=X. Use the INC and DEC switches to adjust the CAN source message ID.
Range = 0 255. [default = 7]
5.2.18. TSC1 RAMP (TSC1/PGN0 control mode RPM ramp speed)
This menu item allows configuration of the engine RPM ramp speed in TSC1/PGN0 control mode.
The display will show
TSC1 RAMP: X. Use the INC and DEC switches to adjust the ramp speed.
Range = 0 40. [default = 0]
5.2.19. DISPLAY (primary display in pressure mode)
This menu item allow configuration of the display data while operating in pressure mode. The display can show
either engine speed (DISPLAY: RPM), or pump pressure (DISPLAY: PSI). The pump pressure will be displayed in
the correct units of measure (psi, kPa, or bar) selected by the user.
Note: The pressure display cannot be used as the master pressure gauge per NFPA 1901.
Range = RPM or PSI. [default = RPM]
5.2.20. PSI TIME-OUT (pressure time out)
This menu item allows configuration of the low pressure time out. When the TPG is governing in pressure mode
and the pressure falls below 30 PSI the TPG will wait the configured number of seconds to allow the pressure to
rise before dropping to IDLE.
The display will show PSI TIME-OUT. Use the INC and DEC switches to adjust the value desired for the pressure
time out.
Range = 3 seconds to 10 seconds (in 1 second steps). [default = 5 seconds]
5.2.21. ALLOW PRESET (allow RPM preset use when pressure is detected)
This menu item allows enabling/disabling of throttle mode preset usage when pump pressure over 10 PSI is
detected.
The display will show PRESET RPM=X. Use the INC and DEC switches to select Y (yes, enabled) or N (no,
disabled).
Range = Y (enabled) or N (disabled). [default = N]