7.3. Zero calibrate the pressure transducer
The pressure indicated by the TPG may not show ‘0’ when the pump discharge pressure is actually zero due to
ambient pressure and altitude at your locale.
Follow the sequence below to zero calibrate the pressure transducer.
+
Display shows
MENU 04 SECS
and begins counting down. Continue holding IDLE and
MENU until the display shows *SETUP MENU* (4 seconds) and then MENU LEVEL 2
(2 seconds).
3 times
The display shows the menu item: -SENSOR CAL-.
ONCE
Press the INC switch once. The display shows INT:ZERO=XXX.
+ HOLD
Press the INC switch and hold. The display shows DIS:LIVE=XXX. Verify the value is
between 130 and 155. Release the INC switch. The display will show
DIS:ZERO=XXX.
ONCE
Press the PRESET switch once. The display shows NEW ZERO=XXX. Verify the
value is between 130 and 155.
ONCE
Press the IDLE switch once. The display shows —EXITMENU— and then restarts
normal operation.
7.4. Configure the engine control method
The TPG has 4 engine control methods to cover several engine types and configuration.
CFPG Cummins Fire Pressure Governor, uses Cummins proprietary control message to control engine speed.
PGN0 Uses J1939, PGN0 Torque Speed Control message to control engine speed.
SCAN SCANia, uses the Scania bodywork control message 1.
ANLG Uses analog voltage signal to control remote throttle input on engine.
PWM Uses pulse width modulation control signal (12-85%, 400 Hz).
VLVO – Uses Volvo specific PTO control commands for Volvo FE/FL series engines running through a bodybuilder
module.
+
or
Enter menu level 3 by pressing and holding the IDLE switch while entering
the following password.
INC, DEC, DEC, INC, DEC, DEC, INC, INC
ONCE
The display shows the menu item: CONTROL=XXXX (CFPG, PGN0, SCAN, ANLG,
PWM)
OR
Select the desired engine control method: CFPG, PGN0, SCAN, or ANLG
ONCE
Press the PRESET switch once. The display shows ---STORED---. The engine control
method has been saved.
ONCE
Press the IDLE switch once. The display shows —EXITMENU— and then restarts
normal operation.