Indoor Fireplace User Manual

SECTION 5: SERVICE
E-6
LIGHT BULBS
Figure 6
WOODEN EMBER NUTS
Figure 7
WOODEN EMBER NUT
EMBERBED & LOGS
EMBERBED MOUNTING POST
LIGHT BULB HOLDING SPRING
PULL
PULL
1) Turn the Main Power button off.
2) If fireplace has been operating, let the unit cool at
least 2 hours.
3) Open the front glass doors, then slide the mesh
curtains to the sides.
4) Locate the 2 ember bed sucuring nuts on the left
and right sides of the log set. These securing nuts are
disguised as wooden embers (Figure 6). Turn nuts
counter clockwise to loosen, remove and set aside.
5) Securely grab the logs on left and right side and
lift log/emberbed assembly straight up. Once the
emberbed has cleared the support brackets and
threaded rods, bring the log/ember bed assembly
forward and out of the unit and set aside in a safe
place (figure 7).
6) Unhook light bulb spring clips from the bulbs and
unscrew the bulbs (Figure 8). After replacing the light
bulbs make sure to replace the light bulb spring clip.
Remember to replace both of the bulbs at the same
time with clear 120V, 40 watt, E12 socket base bulbs.
Figure 8
This electric fireplace uses (4) clear120V, 40 watt,
E12 socket base light bulbs (candelabra base, B bulb).
The 33EB304GRS only requires (3) clear 120V, 40
watt chandelier candle type bulb.
For your convenience, if a bulb burns out, it is a good
idea to replace all the bulbs at the same time. These
bulbs are available at most home centers, hardware
stores or grocery stores.