Instructions

33
BS1306N_IM 02.11.17
Proceed as follows to clean the lter unit:
1. Empty the dust container as described above.
(Steps 1 - 4)
2. Disassembly of the lter unit
2.1 Turn the coarse lter counter-clockwise from the
guide rails. Pull the coarse lter from the dust
collector.
2.2
Turn the HEPA lter counter-clockwise from the guide
rails. Pull the HEPA lter from the dust collector.
3. You can brush out the HEPA lter. In case of heavy
staining, clean the lters under running water.
4. Let the lters air-dry completely before retting them!
5. Wipe the dust collector with a damp cloth and then wipe
it dry.
6. Assembly of the lter unit
Refer to the adjacent gure.
6.1 Set the HEPA lter with its
3 guides to the inner circle.
Tighten the lter clockwise.
6.2 Set the coarse lter over the
HEPA lter with its 3 guides
in the outer circle. Tighten the
coarse lter clockwise.
CAUTION:
If the lters are not tightened, dirt will enter the engine.
This can damage the motor.
7. Close the bottom plate.
Outlet Filter
The appliance is also equipped with an outlet lter.
The cover of the lter is located on the back of the appliance.
1. Turn the cover counter-clockwise.
2. Remove the non-woven lter and wash it.
3. Let the non-woven lter dry completely in the air, before
reinserting it into the appliance.
4. Close the exhaust lter with the cover. Turn it clockwise
until it is attached to the appliance.
Cleaning
WARNING:
Before cleaning remove the mains lead from the socket.
Under no circumstances should you immerse the device in water
for cleaning purposes. Otherwise this might result in an electric
shock or re.
CAUTION:
Do not use a wire brush or any abrasive items.
Do not use any acidic or abrasive detergents.
Clean the housing with a soft, dry cloth without additives.
For cleaning of the lters, read the chapter “Maintenance”.
Troubleshooting
Problem Possible cause Remedy
The device
does not work.
The appliance is
not connected to
mains power.
Check the connection
to the mains.
Check the position of
the switch.
Problem Possible cause Remedy
Weak suction
power.
The dust collector
is full.
Empty the dust collec-
tor.
The lters are
dirty.
Clean the lters as
described under
“Maintenance”.
CAUTION:
Restart operation only
with dry lters.
There is a foreign
body in the
suction tube or
the nozzle.
Check the accessories
for foreign bodies.