Installation guide

© 2006 directed electronics
23
system status chirps
remote siren silencing
While the siren is sounding, press the arm/disarm button once to silence the siren but
leave the system in the armed state. To disarm the system, press the arm/disarm but-
ton a second time.
NNOOTTEE::
If the remote control battery is low, the siren will generate a single low pitched
chirp when disarming.
multiple event total recall
This will report the last eight system triggers.
1. Press and hold of the PlainView 2 Valet switch.
2. While still holding , arm and disarm the system, then release the button.
3. The LED will start to blink to indicate the most recent trigger and proceed down
to the eighth trigger. If fewer than eight triggers are stored in memory, the LED
will blink continuously until the system is armed/disarmed or the ignition is turned
on. For more information, please refer to the Table of Zones section of this guide.
Action No. of Chirps Description
Arm 2 System armed.
Arm 4 System armed with hood or
trunk bypass zones 5 and 6.
Arm 2 (5-second pause) 4 System armed with door bypass zone 4
Arm 2 (10-second pause) 4 System armed with sensor active
and bypassed zones 1, 3, and 8.
Disarm 1 System disarmed.
Disarm 3 System disarmed with zone violation