Installation guide

© 2006 directed electronics
27
auto lock - off/ignition/rpm
z
Off: The doors will not lock automatically.
z
Ignition: The doors will automatically lock three seconds after the ignition is
turned on unless a door is open at that time.
z
Rpm: The doors will lock when the system sees the engine reach a prepro-
grammed RPM. The H1/4 VIOLET/BLACK or Intellistart must be connected.
auto unlock - off/ignition
z
Off: The doors will not automatically unlock when the ignition is turned off
z
Ignition: The doors will automatically unlock as soon as the ignition is turned off.
auto (passive) arm lock - off/on
z
Off: The doors will not lock when the system passively arms.
z
On: The doors will lock when the system passively arms. This feature only applies
when passive arming is programmed on.
siren duration - 30/60/90
z
The system will sound the alarm for the programmed duration (30/60/90
seconds) during an alarm trigger or when the system is put into panic mode.
second unlock - off/on
z
Off: Second unlock output is pulsed at the same time as the unlock output when
the system is disarmed.
z
On: Second unlock output is active when the arm/disarm button is pressed with-
in 10 seconds of disarming the system.
user selectable features descriptions - column two
set pin code
z
This feature allows the setting of the user's personal PIN code. For more infor-
mation, see programming note #5. The factory default PIN code is 2.
select siren sounds
z
The individual sounds the siren produces during an full trigger alarm can be
customized for owner recognition of an alarm trigger. For more information, see
programming note #3.
fact II - off/on
z
Off: The alarm will respond to zone inputs indefinitely without bypassing.
z
On: The alarm will bypass for 60 minutes zones that are triggered three times