Installation guide

© 2006 directed electronics
31
installer selectable features descriptions - column one
lock pulse single/double
z
Single: One door lock pulse will be output when the system arms.
z
Double: Two door lock pulses will be output when the system arms.
unlock pulse single/double
z
Single: One door unlock pulse will be output when the system disarms.
z
Double: Two door unlock pulses will be output when the system disarms.
lock pulse duration 0.8/3.5 sec
z
0.8 seconds: The door lock pulses will be 800 milliseconds in length.
z
3.5 seconds: The door lock pulses will be 3.5 seconds in length.
delay domelight
z
Off: Smart auto testing will generate a warning to indicate the door is open.
z
On: Smart auto testing will ignore the domelight until it goes off.
accessory output b auto activation
NNOOTTEE::
The accessory output will not auto-activate if programmed to latched setting.
z
Off.
z
Arm: The accessory output will auto-activate when the system is armed.
z
Disarm: The accessory output will auto-activate when the system is disarmed.
z
Both: The accessory output will auto-activate when the system is armed and
disarmed.
installer selectable features descriptions - column two
accessory output a programming
The auxiliary accessory output wire (RED/WHITE) can be programmed for several dif-
ferent types of outputs.
z
P1 0.8 seconds: The pulsed output is disabled with the ignition on or the alarm
armed.
z
P2 0.8 seconds: The pulsed output will operate any time.
z
Timed: The length of output duration set.
z
Latched: The output on/off controlled by button(s) controlling accessory.