Installation guide

© 2006 directed electronics
41
wiring reference guide
BLACK - Ground
BROWN - Speaker Output 1
GRAY - (-) Hood Trigger Input Zone 6
EMPTY
GREEN - (-) Door Trigger Input - Zone 4
VIOLET - (+) Door Trigger Input - Zone 4
BLUE - (-) Trunk Trigger Input - Zone 5
WHITE/BLUE - (-) Accessory B Output (200mA)
GREEN/WHITE - (-) Normally Closed Zone 6
WHITE - Light Flash Output
WHITE - Light Flash Output
WHITE/RED - Light Flash Input
RED - 12V Input
BLACK/WHITE - Domelight Supervision Output 30
RED/WHITE - (-) Accessory Output A (200mA)
ORANGE - Ground When Armed Output (-) 500mA
EMPTY
BROWN - Speaker Output 2
18-Pin Primary Harness