GP500 User's Manual

Smart Au toTest ing
Each time you remotely arm the system, it tests all triggers and sensors. For
example, if the Helmet Theft Prevention System is active, you will receive
the usual 2 chirps and flashes, then, 5 seconds later, there will be 4 chirps
and 4 flashes. If a sensor is malfunctioning, you will receive the usual 2 chirps
and 2 flashes, then, 10 seconds later, there will be 4 chirps and 4 flashes.
Note that when you receive these indications that the system will still arm
even though a trigger or sensor is malfunctioning.
NOTE: Since this is a warn ing in di ca tion, you will hear
the 4 chirps even if you use the chirp muting feature.
n Specific malfunction identification: The system can also
indicate the specific trigger or sensor that is malfunctioning. If you get
the 4-chirp/4-flash signal upon arming, perform the following to
identify the malfunctioning trigger or sensor:
1. Remotely disarm, then turn on the ignition. The LED status indicator will
be flashing, pause, then repeat.
2. Count the number of flashes in one cy cle be tween pauses (for your
con ven ience, the flash cy cle re peats a to tal of 5 times) and re fer to the
fol low ing chart:
14 GP500