CTC-1052-QT-DT35A User Manual Aug 14, 2020
Table of Contents 1. Application Overview .................................................................................................................... 1 1.1. Identifying The Parts ______________________________________________________1 1.2. The Power Supply _________________________________________________________2 1.3. Insert SIM Card ___________________________________________________________2 1.4. How to install the Control Panel _____________________________________________2 1.5.
5.1.3. CTC-1052-QT-DT35A Low Battery ............................................................................................................. 38 5.1.4. CTC-1052-QT-DT35A Battery Disconnection .......................................................................................... 38 5.1.5. Devices Low Battery ..................................................................................................................................... 39 5.1.6. Automatic Check-in Report = Periodic Test Call ...
4. Microphone 1. Application Overview 5. Cellular Signal Strength Indicator 1.1. Identifying The Parts 6.
— When pressing the button to power on the panel, the panel will emit two beeps. rechargeable battery inside CTC-1052-QTDT35A, which serves as a back-up in case of a power failure. — Around 30 seconds after powered on, the cellular module will be activated, the panel will play voice prompt “Searching for Cell Signal”. When GSM registration is scuccessful, the panel will play voice prompt “System Ready”.
Locating a suitable position for the Control Panel The Control Panel requires main power and a constant cellular network reception. The Control accessible. The Control Panel should not be placed in a damp location, such as a bathroom. The Control Panel should not be placed close to any heat source, such as microwave ovens, which can reduce signal strength.
1. Press and hold the Learn Button of the CTC-1052-QT-DT35A. When pressed, the CTC-1052-QT-DT35A will emit one beep sound initially, and then emit a double beep on the 6th second followed by a voice prompt “Release the button, Ready to learn sensor.” Release the Learn Button right after the double beep and the voice prompt. 2. Learn-in the Devices There are three methods to learn in devices: command learning, local learning, and using Device ID. The system can learn a total of 20 sensors.
3. Remove the Devices 4. System Configuration There are two methods to remove learned-in devices: command removing, local removing, and SMS command removing. Three CTC-1052-QT-DT35A programming modes are available: Remote Programming Mode, SMS programming, and PC Programming Mode. 3.1. Command Removing Command Removing 4.1. Remote Programming Mode The user can use Commands 80-82 to remove learned-in devices from the system. 1. Command 80 is used to remove ALL previously learnt-in devices.
Step 2. Enter 8744 (the default 4-digit Access Code) followed by #, via the phone set. Long beep: Command failed 4. Function Selection = According to different Command you will have different entering in this part, e.g. Tel. Number, Account number, etc. Step 3. CTC-1052-QT-DT35A will respond with two quick beeps to indicate it is ready for Remote Programming Commands. Step 4. You are now in Programming Mode. Proceed to program by referring to the Command in section 4.2 Programming Your CTC-1052-QT-DT35A.
can hear one beep from the telephone speaker that indicates the programming is successful. When an incoming call matches with any of the programmed Caller ID(s), CTC-1052QT-DT35A will auto-answer the call without checking access code or any button press. If you hear CTC-1052-QT-DT35A emit one beep instead, that means the programming of the 1st telephone number has failed. Please repeat the programming steps again.
overwrite the setting. The Tel. number selected in Command #7 will not be used for alarm and/or status reporting. Command (05): Select which telephone number & GPRS/IP (1-6) is/are to be used for Alarm Reporting. Command (06): Select which telephone number & GPRS/IP (1-6) is/are to be used for Status Reporting. Available Key-in options: Tel. Number / IP Address Function Selection Sequence 5th & 6th GPRS. #s (56) 1st, 2nd & 3rd Tel. #s (123) 1st, 2nd & 4th Tel. #s (124) 1st , 3rd & 4th Tel.
Commands (20-24) are used to program the Alarm reporting method for each Tel. Number. Command (20): Program the same Alarm Reporting Method for all 4 Tel. Numbers. Command (21-24): Program the alarm reporting method for the 1st-4th Tel. Numbers respectively. selected: Once alarm or emergency data is successfully transmitted, the CTC1052-QT-DT35A will automatically send out a SMS (CID) Message.
Emergency Button Enable Command 37 The Help Button can be enabled or disabled to send an Emergency alarm report: Function Selection (0) (1) AC Fault Report Result The CTC-1052-QT-DT35A can be programmed to send a Fault Report when an AC power failure is detected. Function Selection OFF (Disable) (0) ON (Enable) Factory Default is set as (1), ON. OFF: Pressing the Help Button is unable to send an emergency alarm.
function is enabled), CTC-1052-QT-DT35A will auto-answer the call after the 1st-2nd ring and waits for Access Code (default is 8744) and the (#) key entry within 15 seconds. When the correct Access Code is received, CTC-1052-QT-DT35A will then open a FullDuplex Communication to allow the Call Recipient to speak to CTC-1052-QT-DT35A directly. The Access Code must be entered within 15 seconds. Otherwise, CTC1052-QT-DT35A will disconnect the call automatically.
Command 43 Periodic Test Call CTC-1052-QT-DT35A can be programmed to make test calls periodically (every 0–7 days, 0-23 hours, and 0-59 mins). Function Selection (000000) (DDHHMM) DD: (00) - (07) HH: (00) - (23) Result Periodic Test Call will only function with telephone numbers assigned to SMS reporting method in Command 20-24. Command 44 Movement Detector 3. Only workable by entering 2 digits. detected by PIR The reporting method for mobility alarm is the same as the emergency alarm.
Command 47 Off-Set Time After the Control Panel‘s power is supplied, the time of the Check-in Report starts calculating. According to the setting of Off-Set Time, the Control Panel will send Check-in Report once, and then send report according to the setting of Command 43 - Test call. (3) (4) 6 Days (5) 8 Days (6) 9 Days (7) 10 Days 7 Days Factory default is set as (0) Disable. No code is sent to Monitoring Center.
(5) Sensitivity Level 5 (Highest) Factory default is set as (3)Sensitivity level 3. High Temperature Reporting Factory Default is set as (0800), 800ppm This function is used to adjust speaker volume. To set speaker volume in different communication channels, please set different parameters.
Command 64 Microphone Sensitivity Adjustment This function is used to adjust microphone sensitivity. The microphone sensitivity only can be adjusted in the two-way mode. This command is used if a fall is detected. If an emergency alarm is triggered by pressing the Active Button on Fall sensor, the guard time delay time is determined by Command 42. To set the microphone sensitivity with a number, ranging 1 to 5. This value represents the received sound source range.
Function Selection Result (0) Any DTMF (1) OFF-HOOK is learnt-in successfully. Adding a device for a second time is prohibited unless it is removed from the system first. If one long beep is emitted instead of 2 beeps, it indicates: Command 80-82 Remove Devices CTC-1052-QT-DT35A can be programmed to remove ALL previously learnt devices by entering (80) followed by (#). The device has already been learnt-in. When the 21st device is attempted to learn-in.
Learning can only be completed within the signal reception range of CTC-1052-QT-DT35A. If no signal is received within 20 sec, CTC-1052-QT-DT35A will emit a long beep and automatically return to Programming mode. 4.3. SMS Remote Programming CTC-1052-QT-DT35A can be programmed via SMS commands. Step 3: CTC-1052-QT-DT35A will emit 2 beeps to indicate the device is learnt-in successfully.
4.3.1 CTC-1052-QT-DT35A SMS Remote Programming Command Table If the SMS Keyword is set as PROG, and Access Code is set as 8744 (factory default).
CORRESPONDING DTMF CHARACTER COMMANDS 22# 23# 24# 31# ITEM Reporting method for Telephone number 2 Reporting method for Telephone number 3 Reporting method for Telephone number 4 Ringer enable for incoming calls COMMAND EXAMPLE & USAGE DEFAULT FMAT2 PROG 8744 FMAT2:0 To set the reporting method for Telephone number 2 3=Speech, 4=SMS CID 3=Speech FMAT3 PROG 8744 FMAT3:0 To set the reporting method for Telephone number 3 3=Speech, 4=SMS CID 3=Speech FMAT4 PROG 8744 FMAT4:0 To set the reporting
CORRESPONDING DTMF CHARACTER COMMANDS 49# ITEM Supervision COMMAND SUPPR 53# Prompt LANGU 54# Fall Sensor Sensitivity FALSN EXAMPLE & USAGE PROG 8744 SUPPR:0 To set the supervision timer 0=Disable, 1=4 Days, 2=5 Days, 3=6 Days 4=7 Days, 5=8 Days, 6=9 Days, 7=10 Days DEFAULT 0 = Disable PROG 8744 LANGU:0 To set voice prompt language.
CORRESPONDING DTMF CHARACTER COMMANDS ITEM COMMAND --- Password GPASS PROG 8744 GPASS:65536 To set/change the password Input 1 to 5 digits --- Reset to factory default FTSET PROG 8744 FTSET:YyS --- Delete Device DEVDL PROG 8744 DEVDL:SCMD To delete devices learnt into the panel. SCMD: 80 = delete All Devices.
4.4 PC Programming Mode The 1052-QT-DT35a-Tool is a programming software that provides intuitive graphical interface for you to program the panel easily from your computer, instead of entering complex DTMF commands from your phone or sending complex SMS text messages from a mobile device. System Requirement: Microsoft Windows 7, Windows 8 or Windows 10 operating system USB Serial Port supported. To enter PC programming mode: Panel Connection Step 1. Plug a DC 12V 1.
Using the 1052-QT-DT35a-Tool programming software Step 6. After installing the USB driver, you can start programming with 1052-QT-DT35a-Tool programming software via USB port. To download 1052-QT-DT35a-Tool programming software, open your browser and type below URL in the address bar: http://www.climax.com.tw/climax-download-1052qt-dt35atool.html. Step 7. 1052-QT-DT35a-Tool is a portable application and requires no installation.
Step 8. Select the COM port generated for CTC-1052-QT-DT35A after installing the USB Driver (the USB port connected to CTC-1052-QT-DT35A), enter the password (default 8744), and then click “Open”. Step 9. A “Read All command success!” message will pop up. Click “OK”, and the current 1052QT-DT35A settings will be displayed.
4.4.1 Function Tabs To program the CTC-1052-QT-DT35A Control Panel, click on different function tabs to see and edit CTC-1052-QT-DT35A functions. 4.4.1.1 Report The “Report” tab allows the user to configure report settings. 21# - 24# Reporting Method [Tel. Number 1-4]: - You can program the Alarm reporting method for each Tel. Number (1st-4th Tel.) by selecting from each drop-down menu respectively. Available reporting methods include Speech and SMS CID.
APN Name for GPRS: Enter the name of an access point for GPRS. Please inquire your SIM card service provider for your APN. User Name: User name is offered by your SIM card service provider. Please inquire your service provider for your GPRS username. If no username is required, you may skip this step. Password: Password is offered by your SIM card service provider. Please inquire your service provider for your GPRS password. If no Password is required, you may skip this step.
# Ringer Enable for Incoming Calls: - When disabled, CTC-1052-QT-DT35A will operate silent for an incoming call. - When enabled, CTC-1052-QT-DT35A will sound a ring tone as an audio alert for an incoming call. The user can answer the incoming call by pressing the HELP BUTTON or Pendant Button. 32# Audible Fault Alert: - When turned on, CTC-1052-QT-DT35A will sound warning beeps every 30 seconds for AC Failure. - When turned off, CTC-1052-QT-DT35A will NOT sound warning beeps for a fault situation.
1052-QT-DT35A will automatically hang up the line and start a 5-minute waiting period to auto answer any incoming phone calls from the Monitoring Center. - When selected as “Follow-On & Call-Back”, after a successful reporting to the Monitoring Center, CTC-1052-QT-DT35A will automatically enter specific Follow-On mode. Once FollowOn Mode is terminated, CTC-1052-QT-DT35A will automatically start a 5-minute waiting period to auto answer any incoming phone calls from the Monitoring Center.
47# Off-Set Time: - After power is supplied or re-supplied to the Control Panel, the first auto check-in report will be made according to Offset Period setting. This is used to test whether the CMS is able to receive the report from the Panel accurately. - After this test report is sent, the Control Panel will then send reports at regular interval based on the setting of the Periodic Test Call. 49# Supervision: - This option is used to enable system Supervision function.
The Device tab allows user to learn in or remove devices from CTC-1052-QT-DT35A. The system can learn a total of 20 sensors. All learnt-in devices will be assigned to zone 1-20 sequentially. 93# Learn-In Silent Device: - This is used for learning in silent devices. When CTC-1052-QT-DT35A receives the alarm signal from a Silent Device, it will not sound any warning beeps during Reporting and Guard time period. 94# Learn-In Device: - This is used for learning in non-silent devices.
Step 2: Press the Device Button within 20 secs, a “Learn Device success!” message will pop up to indicate successful learning. Learning can only be completed within the signal reception range of CTC-1052-QT-DT35A. If no signal is received within 20 sec, a “Learning Fail” message will pop up, and CTC-1052QT-DT35A will automatically return to Programming mode. Adding a Device for a second time is prohibited unless it is removed from the system first.
82# Remove Zone 2 Device - Click “Remove” to remove zone 2 device from CTC-1052-QT-DT35A. A message “Remove Zone 2 Device command success!” will pop up. 4.4.1.6 Caller ID The Caller ID tab allows the user to program Caller IDs. Click the subtab down below to proceed. Caller ID 201-210, 211-220: - When an incoming call matches with any of the programmed Caller ID(s), CTC-1052-QTDT35A will auto-answer the call without checking access code or any button press.
- CTC-1052-QT-DT35A will match the numbers starting from the last digit, and verify 10 digits at the most. For example, if a number string 321 is programmed, CTC-1052-QT-DT35A will instantly pick up any call that has 321 as the last 3 digits. If a number string 17605851848 is programmed, CTC-1052-QT-DT35A will instantly pick up any call that has 7605851848 as the last 10 digits. The first digit "1" of the Caller ID will be ignored. Click “Write” when you have completed all settings. 4.4.1.
57# CO2 concentration: - Set the CO2 Alarm Reporting threshold. (0 - 9999ppm) - Factory Default is 800ppm. 4.4.1.9 Color The Color tab allows user to set the brightness color level. Adjust Brightness Color: - Input the brightness color level (1, 2, 3).
4.4.2 Profile The Profile function allows you to create and edit different setting profiles which can be easily accessed in the future for quick programming. Current Setting After reading the configuration of CTC-1052-QT, the Profile scroll down bar will now display “Current Setting” indicating that the 1052-QT-Tool is now displaying the current CTC-1052-QT configurations. Selecting different tabs will show the current values of each setting.
After entering the profile name and clicking OK, the new profile will be saved Apply profile If you wish to apply all the configuration of a profile into 1052-QT-Tool, go to each individual page and click on all the “Write” buttons, or just click the “Write All” button to make sure all settings are programmed into 1052-QT-Tool. Profile Manager Click on “Profile Manager” to manage the profiles: Delete Profile Select a profile and click on “Delete Profile”.
Select “Yes” to delete the profile, or “No” to return to the previous page. Profile Backup & Transfer The profiles that you created and saved are stored as text files in the “Profile” folder under the directory where the 1052-QT-Tool files are extracted in your local computer. (Please see pictures below as examples.
Auto-Answer Numbers 5. Operation The Control Panel can program up to 20 AutoAnswer Numbers. If a user calls the Control Panel using an auto-answer number, the Control Panel will pick up the call and instantly open up a two-way communication with the caller. 5.1. Idle Mode When the system is in Idle Mode, CTC-1052QT-DT35A is ready to execute the following functions: The Control Panel will auto-answer calls from the auto-answer numbers and are unaffected by Command #31.
absence of battery in the following cases: Battery not connected Battery failure. QT-DT35A will emit a voice prompt reminder “Inactivity timer expiring, please reset.” every 5 minutes to notify the user for 30 minutes. When the battery disconnection lasts for 10-15 minutes, CTC-1052-QT-DT35A will report to the Monitoring Center and the GREEN LED will flash slowly.
panel will send Low Temperature Restore report to CMS. With the phone number 0987654321, the format should either INCLUDE or EXCLUDE Contry Code, which is “886” for Taiwan as below: INCLUDE Country Code EXCLUDE Country Code 5.2. Alarm Activation +886987654321 0987654321 Step 4. Remove the SIM card from the Mobile phone and insert it back into SIM Card holder on Panel. When an alarm is triggered, CTC-1052-QTDT35A will enter the Guard Time Delay period (see Command 42).
this step. The Guard Time Delay triggered from a fall detection (of a Fall Sensor) has its own timer (programmed using Command 66). The CTC-1052-QTDT35A will play voice prompt “A fall has been detected,” to notify the user; and “Fall detection has restored, cancelling help call” voice prompt, when fall detection has been cancelled. IP Address: Central Monitoring Station server IP. Please refer to 4.3.
the communication time to its preset duration. Please note that when a particular DTMF key is pressed, its designed shortcut function will be executed & the communication time will be extended at the same time. Pressing the Reset Button can also terminate the call. The Control Panel will only allow one call per call-back mode. Terminating a call during call-back period will therefore terminate the call-back mode. Call-back option is disabled by default.
Way” communication mode. 2. Control Panel will try all report destinations for up to 15 times in total. 3. If more than 1 report destinations are set to a report method (e.g. GPRS), the panel will consider the report method to be successful if reporting to one of the destinations succeeds. Control Panel will completely stop reporting to this report method after receiving a successful report. 4.
automatically exit Walk Test Mode after 3 minutes. 5.3 Walk Test (Range Test) Walk Test, or Range test, is a test to check whether learned-in devices are within signal range. 5.3.3. In Idle Mode You can conduct Walk Test in CTC-1052-QTDT35A under 3 different modes as listed below. Idle Mode is only applicable to Smoke Detector (SD), Carbon Monoxide Detector (CO), Motion Sensor (IR), and Water Sensor (WS). 5.3.1. In Learning Mode Step 1.
will be established. Or the test call can be routed to a voicemail by CMS. 6. Appendix 6.1. CID Event Code The message composition for CID Event code is in the form: 5.6 Factory Reset CTC-1052-QT-DT35A will clear all programmed parameters by the following sequence: ACCT MT QXYZ GG C1C2C3 Step 1. Press the Power Button to power off the panel. And is explained in the following table: Step 2. Hold down both the HELP & RESET buttons while pressing the power button again to power on the panel.
When the Test Button of the Smoke Pendant (WTR) is Low on Battery, the Green LED flashes every 2 seconds. Detector (SD) is pressed. 120 - Fall emergency When the IR Tamper is opened.
6.2.
DTMF DTMF CHARACTER COMMANDS ACK 43# Bi 44# Bi 46# Bi 47# Bi 49# Bi 53# Bi 54# Bi 55# Bi 56# Bi 57# Bi 63# Bi 64# Bi 66# Bi 76# Bi 77# Bi 80# Bi 81# COMMAND OPERATION Test Call: DDHHMM DD:00-07=0-7 Day(s) HH= 00-23=0-23 Hour(s) MM=00-59=0-59 Min(s) 000000= Disable Mobility time 00= Disable, 01 - 36= 1 - 36 Hours Two-Way Period, 01=1 min, 02=2mins, 03=3mins, 04=4mins, 05=5mins, 06=6mins, 07=7mins, 08=8mins, 09=9mins, 10=10mins.
6.3. CTC-1052-QT-DT35A Voice Prompts The Control Panel plays voice prompts on important occasions to report its condition or remind you to take a specific action. Information on voice prompts is provided in the chart below.
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15, Part 22, Part 24, and Part 27 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.