Owner`s manual

1.2. L-1X and L-1X16 Operational Cycle
The L-1X and L-1X16 Operational Cycle has a total cycle time of 2 minutes (120
seconds). The Timing Diagram and the steps listed below detail the individual functions
that are executed during each Operational Cycle.
Seconds: 0 10 20 30 40 50 60 70 80 90 100 110
120
Instant
Start Rela
F
L
U
S
H
FILL
Start/Sto
p
Detergent
Drain
Flush/Fill
Sanitize
r
Rinse
Pump Motor
WASH
RINSE
Heater
Cam 1
Cam 2
Cam 3
Cam 4
Cam 5
Cam 6
Cam 7
Cam 8
1. With the machine powered up, toggling the START switch begins a cycle.
a) Toggling the START switch energizes both the cam timer motor and the instant
start relay. The instant start relay latches ON the power to the cam timer motor so
that the START switch can be released a moment after it has been toggled without
the cam timer motor losing power.
b) After about 2 seconds, Cam 1—the Start cam—latches ON the power to the cam
timer motor and drops out the instant start relay. The cam timer motor continues
to run for a total of 2 minutes, at which time it switches OFF—resetting the cam
timer—and waits for the next start command.
MODEL L-1X & L-1X16 INSTALLATION & OPERATION MANUAL Rev. 1.16A Page
3