Installation
Electrical Connections
WARNING:
Electrocution or serious injury may result when working on
an energized circuit.
Disconnect power at the main breaker or service disconnect
switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is being
performed on the circuit.
The Main Terminal Block (MTB) is located on the left-rear corner
of the electrical panel.
ATTENTION
A qualiî‚żed electrician must connect the main incoming power to the dishwasher in accordance
with all local codes and regulations or in the absence of local codes in accordance with the
National Electrical Code
Main Terminal Block
VERIFY THE CORRECT VOLTAGE IS SUPPLIED TO THE MACHINE
THE CORRECT SUPPLY VOLTAGE IS 115/208-240VAC/60/1.