The PLC's RS-232 communication port must be configured to use:
DF1 Full Duplex driver
•no parity
no handshaking
CRC error checking.
38,400 bps (recommended), 19,200 bps may also be used.
4.6 Connecting 24 VDC Power to Robot
NOTE: This section provides information on the 24 VDC power supply
and making the 24 VDC power cable. If you have ordered the optional
Starter Kit, then you can skip to “Installing 24 VDC Robot Cable” on
page 54.
Table 4-3. PLC to PLC Server Cable Pin Description
Signal Adept DB-9 Pin AB PLC DB-9 Pin
TD (Transmit Data)
23
RD (Receive Data)
32
RTS (Request To Send)
87
CTS (Clear To Send)
78
SG (Signal Ground)
55
DSR (Data Set Ready)
46
CD (Carrier Detect)
41
DTR (Data Terminal Ready)
14
DTR (Data Terminal Ready)
64