User`s guide

Adept Cobra PLC600/PLC800 Robot User’s Guide, Rev C 61
5. Insert the stripped end of the wire into the right-hand lower opening, then
remove the screwdriver from the top opening. The clamp will close on the wire.
Pull on the wire to confirm it is securely attached in the connector.
6. Visually inspect the connection to make sure that the clamp has closed on the
wire, not the insulation.
7. Repeat this process for the wire from the negative side of the power supply to the
left-hand side of the connector.
Figure 4-8. 24V Connectors
NOTE: Although no damage will occur, the PLC Server will not turn on if
the DC polarities on the XDC connectors are reversed.
4.9 Grounding the Adept Robot System
Proper grounding is required for safe and reliable robot operation. Follow these
recommendations to properly ground your robot system.
Ground Point on Robot Base
The user can install a ground wire at the robot base to ground the robot. See Figure 4-9.
The robot ships with an M8 x 12 stainless steel, hex-head screw, and M8 split and flat
washers installed in the grounding hole. The user is responsible for supplying the ground
wire to connect to earth ground.
Insert small flat-blade screwdriver
to open clamp.
Insert wire, then remove screwdriver
to secure wire in clamp.
positive (+)
negative (-)
24VDC connector
Adept Part # 25040-00201