Installation guide

34
Feature Bank 5 - 4 Pin Alternate Output
Control
1 - Lt Green/Black Output: Controls
the
LT
GREEN/BLACK output activation type
and timing.
Pulse
before
Start
I
During
Unlock
-
1 second pulse when remote start is
activated.
Also a
1 second
pulse when unlock is pressed.
Ground
While
Running - Continuous output for the entire remote start
sequence
until
after the
vehicle
shuts down.
Ignition- Output
becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.
Pulse
During
Crank
- Output becomes active with the same timing as the
starter output wire, during crank
only.
2
- Lt
Blue
Output: Controls
the
LT
BLUE output activation type and timing.
Pulse After
Start
I
During Lock - 1 second pulse after the remote start
sequence and has confirmed the
vehicle
is
running. Also
a
1 second
pulse
when
lock is pressed.
Ground
While
Running - Continuous output for the entire remote start
sequence
until
after the
vehicle
shuts down.
Ignition- Output
becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory-
Output becomes active with the same timing as the accessory
output, drops out during crank.
Pulse During
Crank
- Output becomes active with the same timing as the
starter output wire, during crank only.
3
- Green/White Output:
Controls
the
GREEN/WHITE output activation type and
timing.
Pulse After Shutdown -
2 second pulse after the remote start has
shutdown.
Ground While Running - Continuous output for the entire remote start
sequence until after the vehicle
shuts down.
Ignition-
Output
becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.
Pulse During
Crank
- Output becomes active with the same timing as the
starter output wire, during crank only.
ca6554 Install