OPERATING INSTRUCTIONS
for
LOG SET AS IT COMES FROM THE FACTORY
If a wall switch, thermostat or remote control has been purchased, you must follow installation and operating
instructions on pages 11and 12 of this instruction manual.
HM2-MAN 18,24 & 33 LP and Natural Gas (See FIG. 1)
1. Notice the white marker line between the igniter button and the control knob. This white marker
line is the line-up mark for the control knob.
2. Follow the safety information on page 15 of this instruction manual.
3. Follow the lighting instructions on page 15 of this instruction manual.
4. NOTE: Your log set main burner will ignite when you complete the next step.
5. Once the pilot is lit, rotate the control knob counterclockwise . As you rotate the control knob
counterclockwise , the main burner will ignite on the minimum heat setting. Continuing to
rotate the knob counterclockwise will allow the burner to increase to the highest setting. You
can leave the control knob where you prefer, either at the low or high setting.
6. To turn the main burner OFF, simply rotate the control knob clockwise to the “PILOT
position. This will allow the pilot to continue to burn, until you are ready to burn the set again.
7. Your log set has two settings, HI and LOW. You can burn your log set at the range you prefer.
8. To turn you log set completely off, simply rotate the control knob clockwise to the “OFF”
position. If this is done, the pilot must be re-ignited the next time you use your log set.
HM2-T 18,24 & 33 LP and Natural GAS (See FIG. 1)
1. Notice the white marker line between the igniter button and the control knob. This white marker
line is the line-up mark for the control knob.
2. This log set operates by a thermostatic bulb that is attached to the control valve. The manufacturer
attaches the bulb at a location that should give you fairly accurate operation of the control, however,
the bulb can be relocated to a place farther away from the flame. If this is done, be sure not to crimp
the small tube that attaches the bulb to the valve. This will cause damage resulting in thermostat
malfunction.
3. Follow the safety information on page 15 of the instruction manual.
4. Follow the lighting instructions on page 15 of this instruction manual.
5. NOTE: Your log set main burner will ignite when you complete the next step.
6. Once the pilot is lit, rotate the control knob counterclockwise . As you rotate the control knob
counterclockwise , the main burner will ignite first on the minimum heat setting. Continuing to
rotate the knob counterclockwise will allow the burner to increase to the highest setting.
FIG. 1
IGNITER
CONTROL
KNOB