Energy Guide

Project No.
Tested By
Applicant
Elec-Tech International Co., Ltd.
Test Date
Model No.
Rated Life
Standard/Method
Test Laboratory
Remarks
Jackson Zeng
2/2/2015
ENERGY STAR® Program Requirements Product Specification
for Luminaires (Light Fixtures) Eligibility Criteria Version 1.2
542831XX (where “xx” denotes color temperature, 0110 identifies 2700K, 1130identifies 3000K,
3140 identifies 3500K, 4150 identifies 4000K)
542831XX
4786795152-08
50000 h
DATA SHEET (Luminaires)
UL Verification Services (Guangzhou) Co., Ltd.
ADD: Building A1, 1F & 2F, Nansha Science and Technology Innovation Center, No. 25, South
Huanshi Avenue , Nansha District, Guangzhou 511458, China
ENERGY STAR Requirements
0.000 ± 0.006
0.002 ± 0.006
IES LM-41-13
(fluorescent; renewal
anticipated in 2013)
IES LM-79-08
(solid state)
IES LM-46-04
(high intensity
discharge)
ANSI/ANSLG
C78.81-2010
(for T8)
IEC 60081 data
sheets (for T5)
0.000 ± 0.006
Target Duv and
Tolerance
≥ 200 lumens per head
≥35 lm/W
≥85% of total lumens (0-40° zone)
≥ 200 lumens per lineal foot
≥45 lm/W
≥35% of total lumens(30-60° zone)
0.000 ± 0.006
2725 ± 145
2700K
≥70 lm/W
Downlights:
recessed
surface
pendant
SSL downlight
retrofits
The variation of chromaticity shall be within 0.004 from the
weighted average point on the CIE 1976 (u’,v’) diagram
Luminaire
Minimum
Light Output
&
Luminous
Efficacy
&
Zonal Lumen
Density
≥ 125 lumens per lineal foot
≥29 lm/W
≥60% of total lumens (0-60° zone)
≥12.5% of total lumens
(60-90° zone)
≥ 300 lumens per head
≥35 lm/W
≥95% of total lumens (0-85° zone)
≥ 200 lumens per lineal foot
≥29 lm/W
≥85% of total lumens (0-60° zone)
Sample Size:
1 complete luminaire.
Passing Test:
The luminaire shall pass.
Laboratory test results shall be
produced using the specific models
of lamp and ballast or LED
package, LED module or LED array
and LED driver that will be used in
production.
For downlights, one trim ring and
one reflector may be used with the
three luminaire samples.
Accent Lights
includes line voltage
track heads
Under Cabinet
Outdoor, Wall-,
Porch-, Pendant-,
and Post- Mounted
Luminaires
Portable Desk Task
Item
Ra ≥ 80
ENERGY STAR Requirements
Target CCT(K) &
Tolerance
3465 ± 245
5028 ± 283
Inseparable SSL
Luminaire
0.001 ± 0.006
3045 ± 175
≤ 4.5" aperture: 345 lumens
> 4.5" aperture: 575 lumens
≥42 lm/W
≥75% of total lumens (0-60° zone)
Cove Mount
Methods of
Measurement
and/or Reference
Documents
Supplemental Testing
Guidance
Color
Rendering
Index (CRI)
Color Angular
Uniform
5000K
Correlated
Color
Temperature
(CCT)
3500K
Rated CCT
3985 ± 275
4000K
3000K