Energy Guide

Project No.
Tested By
Applicant
Elec-Tech International Co., Ltd.
Test Date
Model No.
Rated Life
Standard/Method
Test Laboratory
Remarks
Jackson Zeng
2/2/2015
ENERGY STAR® Program Requirements Product Specification
for Luminaires (Light Fixtures) Eligibility Criteria Version 1.2
542831XX (where “xx” denotes color temperature, 0110 identifies 2700K, 1130identifies 3000K,
3140 identifies 3500K, 4150 identifies 4000K)
542831XX
4786795152-08
50000 h
DATA SHEET (Luminaires)
UL Verification Services (Guangzhou) Co., Ltd.
ADD: Building A1, 1F & 2F, Nansha Science and Technology Innovation Center, No. 25, South
Huanshi Avenue , Nansha District, Guangzhou 511458, China
The line transient shall consist of seven strikes of a 100
kHz ring wave, 2.5 kV level, for both common mode and
differential mode.
≥ 3 samples of LED package/LED
module/LED array and LED driver
model combination
ANSI C82.77-2002
sections 6 and 7
Light source shall remain continuously illuminated within
one second of application of electrical power
≥ 3 samples of LED package/LED
module/LED array and LED driver
model combination
1 complete luminaire
Total luminaire input power less than or equal to 5 watts:
PF ≥ 0.5
Total luminaire input power greater than 5 watts:
Residential: PF ≥ 0.7
Commercial: PF ≥ 0.9
Maximum In-
Situ Source
Temperature
ANSI/UL 153:2002
(Sections 124-128A)
ANSI/UL 1574:2004
(Section 54)
ANSI/UL 1598:2008
(Sections 19.7, 19.10-
16)
None referenced
≥ 120 Hz
Luminaires incorporating an integral method of switching
shall not draw power in the off state
1 complete luminaire
None referenced
≥ 3 samples of LED package/LED
module/LED array and LED driver
model combination
ANSI/IEEE C62.41.1-
2002
ANSI/IEEE C62.41.2-
2002
1. In the sample luminaire, the in situ TMPLED
temperature is less than or equal to the temperature
specified in the LM-80 test report for the corresponding or
higher drive current, within the manufacturer’s specified
operating current range.
2. The drive current measured in the luminaire is less than
or equal to the drive current specified in the LM-80 test
report at the corresponding temperature or higher.
At the temperature measurement point for the hottest
location on the driver case (TMPC as detailed by the
driver manufacturer), the measured driver case
temperature at thermal equilibrium shall not exceed the
driver manufacturer’s maximum recommended
temperature during in situ (installed in the luminaire)
operation.
≥ 3 samples of LED package/LED
module/LED array and LED driver
model combination
None referenced
Transient
Protection
Off-state
Power
Consumption
LED
Operating
Frequency
Maximum
Measured
Ballast or
Driver Case
Temperature
Source Start
Time
Power Factor