Installation Guide

7 HOMEDEPOT.COM
Please contact 1-877-527-0313 for further assistance.
Row/Continuous Mounting
Knock out hole
A
NOTE: Listed conduit fittings, listed conduit, and the wires suitable for use with conduits, conduit fittings TYPE: 1/2”.
Liquid-tight flexible conduit connector (Fitting):
Nonmetallic conduit fittings should be UL/CUL listed and
covered under DWTT/7 category for UL514B standard
Liquid-tight flexible conduit :
Nonmetallic conduit should be UL/CUL listed and
covered under DXOQ/7 category for UL1660 standard
NOTE: This lamp is most connected to 10 pcs. This fixture input current is 0.29A (120V-277V) end user should buy the
suitable wires to row mounting as per the input current data.
A1
A2
Dimmer Wire +
Dimmer Wire -
L
N
G
Dimmer Wire +
Dimmer Wire -
L
N
G
1
Remove knock out on fixture end cap
2
Prepare one 7/8 in outer diameter fitting (not included, choose one as
per necessary) to put it between the fixtures, like the below figure.
3
Connecting the wires : Prepare five wires to connect with two fixtures,
please refer to the below figures.