Installation guide

Service Guide
EK-HSG80-UP. B01 Page 15
10.0 Installing the Second HSG80 Controller
Use the following steps to install the second HSG80 controller:
1. Once the controller has restarted install the other controller and its cache module by
starting FRUTIL with the following command:
HSG80> RUN FRUTIL
FRUTIL displays the following:
Do you intend to replace this controllers cache battery? Y/N
2. Enter N(o). FRUTIL displays the FRUTIL Main menu:
FRUTIL Main Menu:
1. Replace or remove a controller or cache module
2. Install a controller or cache module
3. Replace a PVA module
4. Replace an I/O module
5. Exit
Enter choice: 1, 2, 3, 4, or 5 ->
3. Enter option 2, Install a controller or cache module, from the FRUTIL Main menu. FRUTIL
displays the Install Options menu:
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1, 2, 3, or 4 ->
4. Enter option 1, Other controller and cache module, from the Install Options menu. FRUTIL
display the following:
Insert both the slot B controller and cache module? Y/N
5. Enter Y(es) and press return. FRUTIL displays the following:
Quiescing all device ports. Please wait..
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
.
.