User guide

ENTEGRIS, INC. Customer Service Tel. 763-502-0200 Customer Service Fax 763-502-0300 39
NT® INTEGRATED FLOW CONTROLLER WITH DEVICENET™ COMMUNICATION USER GUIDE
SERVICES 3.01 - INSTANCE SERVICES - S-DEVICE SUPERVISOR OBJECT
RE- SUP- PARAMETER
CODE QUIRED PORTED NAME PARAMETERS DESCRIPTION VALUES
0E
hex
Required Yes Get_Attribute_ Attribute ID Retrieves an 1–255
Single (USINT) attribute value
10
hex
Required Yes Set_Attribute_ Attribute ID Sets an Attribute ID = 1–255
Single (USINT); Value attribute value Value = attribute
specific
05
hex
Required Yes Reset None Resets the device
to the self-
testing state
06
hex
Required Yes Start None Moves the device
to the executing
state
07
hex
Optional Yes Stop None Moves the device
to the idle state
4B
hex
Required Yes Abort None Moves the device
to the abort state
4C
hex
Required Yes Recover None Moves the device
out of the abort
state
4E
hex
Required Yes Perform_ Test ID Causes the device 0 = Standard
Diags (USINT) to perform a set 1-63 = Reserved
of diagnostic 64-127 = Device profile
routines 128-255 = Vendor specific
ENT48906 10/15/04 8:12 AM Page 39