User guide

NT® INTEGRATED FLOW CONTROLLER WITH DEVICENET™ COMMUNICATION USER GUIDE
48 Customer Service Tel. 763-502-0200 Customer Service Fax 763-502-0300 ENTEGRIS, INC.
S-Sensor Calibration Object (64
hex
)
Class
ATTRIBUTES 64.0 - CLASS ATTRIBUTES - S-SENSOR CALIBRATION OBJECT
ACCESS DATA ATTRIBUTE
ATT. ID REQUIRED SUPPORTED RULE NAME TYPE DESCRIPTION VALUES
1 Optional Yes Get Revision UINT Object revision = 01
SERVICES 64.0 - CLASS SERVICES - S-ANALOG SENSOR OBJECT
RE- SUP- PARAMETER
CODE QUIRED PORTED NAME PARAMETERS DESCRIPTION VALUES
0E
hex
Required Yes Get_Attribute_ Attribute ID Retrieves an 1–255
Single (USINT) attribute value
4B
hex
Required Yes Get_All_ None Retrieves a list See response below
Instances of all supported
instances
SERVICE DATE FIELD PARAMETERS - GET_ALL_INSTANCES - SUCCESS RESPONSE
PARAMETER REQUIRED DATA TYPE DESCRIPTION VALUES
Size of list Required UINT Specifies the number Number of
of elements in the calibrations
array in the list
List of Required if ARRAY of: Supported list
calibrations Size > 0
STRUCT of: Supported calibration
UINT S-Sensor calibration = 01
object instance ID
UINT Calibration ID number = 0-65535
UINT Valid sensor instance = 01
Instance 1
ATTRIBUTES 64.1 - INSTANCE ATTRIBUTES - S-SENSOR CALIBRATION OBJECT 1
ATT. RE- SUP- ACCESS DATA ATTRIBUTE
ID QUIRED PORTED RULE NV NAME TYPE DESCRIPTION VALUES
3 Required Yes Get NVF Calibration UINT Identifies the [default] = 0
ID Number calibration
(e.g., fluid type)
4 Required Yes Get NVC Valid UINT S-Analog sensor = 01
Sensor object instance ID
Instance for which this object
instance is valid
ENT48906 10/15/04 8:12 AM Page 48