Service manual

STS Assignment Error
(SSS)
“SS_” = Unassigned Switch(es)
“UA_” = Unassigned Column (5.1 Only)
“DA_” = Doubly Assigned Column (5.1
Only)
Automatically cleared when assignment error is
corrected through SSS program mode.
“ER-9”
MDB Bill Validator Error
(Valid only with MDB
Interface)
Press Mode Switch 1 time to identify:
“BOPN” = Bill Box Open
“BS” = Bill Validator Sensor Error
“BJ” = Bill Jammed
“BILL” = Defective Motor
“BRCH” = ROM Checksum Error
“BFUL” = Bill Box Full (5.1 Only)
After repair, press any selection switch for 2
seconds while ER-9 is displayed.
SALES INFORMATION
DESIRED DISPLAY ACTION FOR DESIRED DISPLAY NEXT CONTROL ACTION
TOTAL HISTORICAL
VENDS
“CANS”
(Non-Resetable)
If No Errors:
No action is required to display total
vends
If Error Codes are not cleared:
Press selection switches 1 and 2 at
the same time
After 15 seconds, control will automatically go to
alternate test vend operation.
VENDS BY SELECTION
(Since Last Reset)
Pressing any selection button will display
unit sales for that selection since the reset
button was last pressed.
After 15 seconds, control will automatically go to
alternate test vend operation.
TOTAL HISTORICAL
CASH
“CASH”
(Non-Resetable)
From Total Vends:
No action is required to display
total cash
From vends by selection:
Press selection switches 1 and 2 at
the same time
After 15 seconds, control will automatically go to
alternate test vend operation.
NOTE: OPTIONAL DOOR CLOSED DATA RETRIEVAL
If desired, “Total Historical Vends” and “Vends By Selection” may also be retrieved with the door closed after entering passcode.
(Refer to “OPTS”, selection 5). After passcode, vends by selection may be reset by pressing selection switches 1 And 4 at the same
time and holding for 3 seconds.