7.0 Timers (Continued)
7.3 TIMER CONTROL FLAGS
The control bits and their functions are summarized below.
T1C3 Timer mode control
T1C2 Timer mode control
T1C1 Timer mode control
T1C0 Timer Start/Stop control in Modes 1 and 2 (Pro-
cessor Independent PWM and External Event
Counter), where 1 = Start, 0 = Stop
Timer Underflow Interrupt Pending Flag in
Mode 3 (Input Capture)
T1PNDA Timer Interrupt Pending Flag
T1ENA Timer Interrupt Enable Flag
1 = Timer Interrupt Enabled
0 = Timer Interrupt Disabled
T1PNDB Timer Interrupt Pending Flag
T1ENB Timer Interrupt Enable Flag
1 = Timer Interrupt Enabled
0 = Timer Interrupt Disabled
The timer mode control bits (T1C3, T1C2 and T1C1) are detailed below:
Mode T1C3 T1C2 T1C1 Description
Interrupt A
Source
Interrupt B
Source
Timer
Counts On
1
1 0 1 PWM: T1A Toggle Autoreload RA Autoreload RB t
C
1 0 0 PWM: No T1A
Toggle
Autoreload RA Autoreload RB
t
C
2
0 0 0 External Event
Counter
Timer
Underflow
Pos. T1B Edge Pos. T1A
Edge
0 0 1 External Event
Counter
Timer
Underflow
Pos. T1B Edge Pos. T1A
Edge
3
0 1 0 Captures: Pos. T1A Edge Pos. T1B Edge t
C
T1A Pos. Edge or Timer
T1B Pos. Edge Underflow
1 1 0 Captures: Pos. T1A Neg. T1B t
C
T1A Pos. Edge Edge or Timer Edge
T1B Neg. Edge Underflow
0 1 1 Captures: Neg. T1A Neg. T1B t
C
T1A Neg. Edge Edge or Timer Edge
T1B Neg. Edge Underflow
1 1 1 Captures: Neg. T1A Neg. T1B t
C
T1A Neg. Edge Edge or Timer Edge
T1B Neg. Edge Underflow