Instruction Manual

12 - DeviceMaster 500 User Guide: 2000501 Rev. A Hardware Installation
Hardware Installation
1-Port Embedded Installation
Installing the DeviceMaster 500 1-Port Embedded system follows these basic
steps:
Building the serial ribbon cable (below).
Mounting the Embedded 1-Port
on Page 13 and installing light pipes.
Attaching the Network and Serial Cables
on Page 14.
Connecting the Power and Verifying Installation
on Page 14.
Observe proper ESD techniques when handling the DeviceMaster 500.
Building the Serial
Ribbon Cable
Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 500 1-Port Embedded IDC10 connector (J3).
Caution
J3 Header RS-232 RS-422 RS-485
1 CD Not used Not used
2 DSR Not used Not used
3 RxD RxD- Not used
4 RTS TxD+ TRX+
5TxDTxD-TRX-
6CTSRxD+Not used
7 DTR Not used Not used
8 RI Not used Not used
9 GND Not used Not used
10 Not connected
Pin 1
Pin 6
1
2
9 10
Ribbon Cable
10-Pin
Socket
Pin 5
Pin 9
DB9
Male
J3