Operating instructions

19
W415-0680 / 04.10.08
BCDV42CF VERTICAL TERMINATION
when (H
T
) > (V
T
)
Simple venting confi gurations
See graph to determine the required vertical rise V
T
for the required horizontal run H
T
.
FIGURE 40
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
H
T
The shaded area within the lines represents acceptable values for H
T
and V
T
.
MAXIMUM
VERTICAL
RISE IN
FEET
V
T
For vent confi gurations requiring more than one 45º and one 90° elbow the following formulas apply:
Formula 1:
H
T
< 3
V
T
Formula 2:
H
T
+
V
T
< 40 feet
90°
90°
90°
H
1
V
1
V
2
45°
H
2
FIGURE 41
V
1
= 1 ft
V
2
= 1.5 ft
V
T
=
V
1
+
V
2
=
1 + 1.5 = 2.5 ft
H
1
= 6 ft
H
2
= 2 ft
H
R
= H
1
+ H
2
= 6 + 2 = 8 ft
H
O
= .03 (one 45° elbow + three 90° elbows - 135°)
= .03 (45 + 90 + 90 +90 - 135) = 5.4 ft
H
T
= H
R
+ H
O
= 8 + 5.4 = 13.4 ft
H
T
+ V
T
= 13.4 + 2.5 = 15.9 ft
Formula 1: H
T
< V
T
3V
T
= 3 x 2.5 = 7.5 ft
13.4 < 7.5
Since this formula is not met, this vent confi guration is unacceptable.
Formula 2: H
T
+ V
T
< 40 feet
15.9 < 40
Since only formula 2 is met, this vent confi guration is unacceptable and a new fi replace location or vent confi gura-
tion will need to be established to satisfy both formulas.
Example 5:
V
1
= 1.5 ft
V
2
= 8 ft
V
T
=
V
1
+
V
2
=
1.5 + 8 = 9.5 ft
H
1
= 1 ft
H
2
= 1 ft
H
R
= H
1
+ H
2
+ H
3
= 1 + 1 + 10.75 = 12.75 ft
H
O
= .03 (two 45° elbows + three 90° elbows - 135°)
= .03 (45 + 45 + 90 + 90 +90 - 135) = 6.75 ft
H
T
= H
R
+ H
O
= 12.75 + 6.75 = 19.5 ft
H
T
+ V
T
= 19.5 + 4.5 = 24 ft
Formula 1: H
T
< V
T
3V
T
= 3 x 2.5 = 7.5 ft
13.4 < 7.5
Formula 2: H
T
+ V
T
< 40 feet
24 < 40
Since both formulas are met, this vent confi guration is acceptable.
90°
90°
90°
H
1
V
1
V
2
45°
H
2
H
3
FIGURE 42
45°