Operating instructions

20
W415-0680 / 04.10.08
BCDV36CF(G) PRE-INSTALLATION PREPARATION
REAR EXIT:
(THIS PROCEDURE IS NOT REQUIRED FOR THE BCDV42CF)
REMOVING THE VALVE ACCESS DOOR
1. The valve access door rotates on the pins attached to the side frame. Lift the valve access
door off the pins to operate the main glass door.
FIGURE 43
FIGURE 45
For optimum performance, it is recommended that all horizontal runs have a 1" rise per foot.
DOOR OPERATION
To access the lower door latch, open the Valve Access Door as illustrated. Release the top
and bottom door latches, located at the right side of the door.
FIGURE 44
FIGURE 44
Before attaching elbows to the collars on the back of the fi replace, 1½" will need to be
trimmed off the 4" collar.
From inside the fi rebox, insert the 4" fl ue pipe / gasket assembly (provided) through the
rear of the fi rebox.
Secure the gasket assembly to the rear and top of the unit using 4 #8 x 3/4" Hex Head
Wildrill screws supplied.
Do not over tighten. The gasket needs only to be snug against the fi rebox. FIGURE 45.
1. Remove the 7" diameter cap from the top of the fi replace and re-secure it over the 7" collar
located at the rear of the unit. Press fi rmly on the cap while securing to ensure an airtight seal. Do
not damage the gasket.
FAILURE TO INSTALL THE CAP WILL CAUSE THE FIREPLACE TO FUNCTION IMPROP-
ERLY AND CAN CAUSE INJURY OR PROPERTY DAMAGE.
2. Remove the plate covering the 4" diameter fl ue opening (seen inside the top of the 7" diameter collar) and discard. Try not
to disturb the retaining ring or the gasket beneath. Re-secure the ring and gasket using the screws removed from the plate.
3. From inside the fi rebox, insert the 4" fl ue pipe assembly through the heat shield and out through the retaining ring. Secure
the assembly to the rear and top of the unit using 4 #8 x ¾" Hex Head Wildrill screws supplied. Do not over tighten. The gasket
needs only to be snug against the fi rebox. FIGURE 46.
TOP EXIT:
FIGURE 46
HORIZONTAL VENT SECTIONS: - A minimum clearance of 1" at the bottom and sides of the vent and 2" at the top on
all horizontal runs to combustibles is required. The fi restop spacer (W010-1774) supplied with the unit must be used to
maintain this clearance.
VERTICAL VENT SECTIONS: - A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required
except for clearances in fi replace enclosures. See "MINIMUM ENCLOSURE CLEARANCES" section. Use fi restop spacer
W500-0096 (not supplied).
INSTALLATION
WALL AND CEILING PROTECTION
BCDV36CF(G)
!
WARNING