Operating instructions

32
W415-0680 / 04.10.08
The fi replace requires a minimum enclosure height of 49“. For
temperature requirements, the enclosure space around and
above the fi replace must be left unobstructed.
This fi replace requires a minimum of 6 1/2" of cement board or
non-combustible equivalent above the top of the fi re
place.
PHAZER
TM
logs and glowing embers exclusive to Wolf Steel
Ltd., provide a unique and realistic glowing effect that is differ-
ent in every installation. Take the time to carefully position the
glowing embers for a maximum glowing effect.
Log colours
may vary. During the initial use of the fi replace,
Log colours may vary. During the initial use of the fi replace the
colours will become more uniform as colour pigments burn in
during the heat activated curing process.
LOG PLACEMENT
TAB
SIDEVIEW
FIGURE 94
FIGURE 94
FIGURE 95
FIGURE 96
FIGURE 96
FIGURE 97
FIGURE 97
FIGURE 98
FIGURE 98
2. Move the two small logs (#2 & #3) into position, lining up
the studs located on the burner with the holes on the bottom
of the logs. Ensure that the small logs sit fl at on the burner.
3. Place the bottom of the left crossover log (#4) against the
left fi rebox side and pulled forward to the grate.
The top of the log should rest in the pocket on the back log.
4. Position the base end of the center log (#5) against the
middle grate post with the other end of the log resting in the
pocket of the left crossover log.
5. Place the bottom of the right crossover log (#6) against the
right fi rebox side and pulled forward to the grate. The top of
the log should rest in the pocket provided on the center log
(#5).
BCDV36CF FINISHING
1. Place the back log (#1) onto the log sup-
port tray and in front of the tabs. The tabs
maintain an air space between the log and
rebox back to facilitate combustion air fl ow.
Ensure that the back of the log rests against
the brackets on the back wall of the fi rebox.
FIGURE 99
FIGURE 99
FIGURE 94b
FIGURE 94a