OPTIONAL BLOWER INSTALLATION
BCDV36CF(G) ACCESSING THE BLOWER
1. Remove the valve access door.
2. Open the main door.
3. Carefully remove the logs.
3a. (BCDV36CFG) Carefully remove the glass and glass ember
tray.
4. Remove the 7 screws illustrated in Fig. 113a and lift out the log
support.
4a. (BCDV36CFG) Remove the top defl ector and porcelain panels from the fi rebox.
(See Figure 110).
5. Remove the 8 perimeter screws as illustrated in Fig. 113a and lift out the burner
base. (The gas line fl ex-connector should provide suffi cient movement to permit shift-
ing the burner assembly to the side).
FIGURE 113a
FIGURE 113a
FIGURE 113b
FIGURE 113b
BCDV42CF ACCESSING THE BLOWER
1. Remove the main door using the instructions on Pg #29.
2. Carefully remove the logs.
3. Remove the grate by lifting it off of the two securing pins.
4. Remove the 6 screws illustrated in Fig. 113b and lift out the
log support. Be careful not to lose the spacers for the screws
indicated.
5. Remove the 7 perimeter screws as illustrated in Fig. 114 and
lift out the burner base. (The gas line fl ex-connector should pro-
vide suffi cient movement to permit shifting the burner assembly
to the side).
6. Reverse procedure to re-assemble.
SPACERS
FIGURE 114
FIGURE 114
FIGURE 115
FIGURE 115
FIGURE 116
FIGURE 117
INSTALLING THE BLOWER
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically con-
nected and grounded in accordance with local codes. In the absence of local codes, use
the current CSA C22.1 C
ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States
If the fi replace was not previously equipped with
a blower: route a grounded 2-wire, 60hz power cable
to the receptacle / junction box. At this point, it must
be strain relieved and insulated.
Because the blower is thermally activated, when
turned on, it will automatically start approxi-
mately 10 minutes after lighting the fi replace and
will run for approximately 30-45 minutes after the
replace has been turned off. Use of the fan increases the output of heat.
The three slots on the blower mounting bracket allow ease of adjustment when attaching the blower. For a quiet running
blower, do not allow the assembly to sit on the fi rebox base.
Slide the vibration reducing pad (A) into the clip (C) and up against the threaded stud (B) at the other end. The blower must be able to
be positioned entirely onto the pad.
To ease installation of the blower, remove the hinge screen and valve control door (lower louvres) from the base of the fi replace.