Operating instructions

42
W415-0680 / 04.10.08
These settings are for (maximum) horizontal termination. Adjust-
ment may be required depending on fuel type, vent confi guration
and altitude.
Closing the air shutter
will cause a more yel-
low fl ame, but can lead
to carboning. Open-
ing the air shutter will
cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The
ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame
colour to be established.
Air shutter adjustment must only be done by a qualifi ed in-
staller!
The front of the fi replace becomes very hot during
operation. Let the fi replace cool completely before
conducting service.
NOTE: When removing the glass ember tray make sure the glass
embers are away from the center of the screen, exposing the
burner, before lifting glass ember tray out.
When replacing burner, absolutely no glass can be in cup sur-
rounding the orifi ce. HINT: If glass falls into cup and surrounds
the orifi ce, insert a clean bag into a vacuum cleaner and vacuum
out glass embers or replacement glass embers can be ordered
from Wolf Steel Ltd.
ADJUSTMENTS
VENTURI ADJUSTMENT
FIGURE 128
FIGURE 129
FIGURE 130
VENTURI
FIGURE 131
FIGURE 131
FIGURE 132
FIGURE 133
BCDV36CFG VENTURI ADJUSTMENT
NG
LP
BCDV36CF BCDV42CF
1/16"
1/4"
1/4"
7/16"
BCDV36CFG
0
0
Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce
the gas fl ow.
To access the air shutter, remove the control panel, remove
the two screws that secure the cover to the air housing,
loosen the set screw and adjust air shutter position.
!
WARNING
PILOT BURNER ADJUSTMENT EXCLUDING BCDV36CFG
The alternate access is to remove the glass, glass ember tray and burner from the fi replace and then adjust the air shutter.