Refrigerators and Freezers Operation, Installation and Instruction Manual Refrigerators and Freezers

FIGURE 3
CASTERS MUST BE TIGHT TO CABINET BOTTOM
INSTALLING CONDENSATE EVAPORATOR
No floor drains or plumbing connections are required since all models use an
automatic condensate water evaporating system. All models are supplied with an
electric condensate evaporator pan and mounting bracket packed in the accessory
carton. To install the condensate pan on models, remove both mounting screws
located on the bottom of the cabinet back and install the mounting bracket on the
case bottom as shown in figure 4. Slide the condensate pan onto the bracket,
install the drain tube into the pan making sure it is not blocked or kinked, and plug
the ten foot power cord into the receptacle labeled "vaporizer" located on the case
top electrical box.
Important Note:
It is extremely important to be sure that the condensate
pan is plugged into its correct receptacle labeled "vaporizer" and that the
condensing unit is plugged into its correct receptacle labeled "condensing
unit".
- 6 -