Setting Unit Sensitivities
Unit sensitivities indicate the change required in an analog input for the BU-905U-L-T to detect a state change and trigger any mapping that
includes the input.
If you set the sensitivity to a small value, the mappings using the input will trigger on a small change of value. If the input is noisy or variable, this
can congest the radio channel by sending multiple spurious messages. You can overcome this situation by increasing the sensitivity value.
To set unit sensitivities:
1. Open the project.
2. Select the unit you want to change.
3. Select Sensitivities
4. BU-Config shows the sensitivities for the unit:
5. Select the sensitivity you want to change and click Edit Sensitivities .
6. BU-Config shows the sensitivity:
7. Set the sensitivity as required and click OK to set the new value or click Cancel to return to the sensitivity list without changing
the sensitivity.
8. BU-Config will write the new sensitivity value to the module when you reconfigure it.