Installation Guide

Page 1 of 2 300112ID
161-48 INSTALLATION INSTRUCTIONS
WARNING
DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
CAUTION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL
ELECTRICAL/BUILDING CODES.
INSTALLATION AND MAINTENANCE OF THIS UNIT REQUIRES AN ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached. DO NOT SEPARATE
ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING. In regular circumstances the BLACK
wire will be the “Hot” lead and the WHITE wire will be the “Neutral” or “Common” lead. A GREEN or BARE COPPER wire is the “Ground”. In
older buildings, it is always good practice to reconfirm the polarity of the wiring.
NOTICE
The important safeguards and instructions outlined on this sheet
cannot cover all possible conditions and situations that may occur.
It must be understood that common sense, caution and care are
factors that cannot be built into any product. Caution and care must
be supplied by the person(s) installing, operating and caring for
this lighting fixture.
This fixture is designed to be mounted on a correctly installed
standard round or octagon box or a through wiring box with a
plaster frame. The box must be securely mounted to the structure
of the building. The crossbar and hardware supplied should be
used. Directly mounting the fixture to the outlet box may make it
impossible to correctly align the fixture.
FIXTURE PREPARATION
1. Remove the fixture and parts bag(s) from the carton.
NOTICE:
Before discarding the carton, double check the contents
to make certain that all parts are found.
FIXTURE INSTALLATION
1. Attach the crossbar to the outlet box. (The green screw should face the floor).
2. Remove the threaded ring from the screw collar loop. Fully thread the loop onto
the nipple and tighten the set screw. Thread the hex nut onto the nipple and the nipple
into the crossbar. Place the canopy over the screw collar loop and against the ceiling.
Adjust the nipple so that 1/4" of threads on the screw collar loop extend beyond the canopy.
Tighten the hex nut against the crossbar. Using the ring, install the canopy.
3. Open the end links of the chain. Attach the chain to the screw collar loop.
Hang the fixture on the chain at the desired height. Remove excess chain.
Close the chain links. Unscrew the ring from the screw collar loop.
Allow the ring and canopy to slide down the chain to the fixture.
WARNING
The use of chain pliers for opening and closing links of chain is required. The use of tools other than chain pliers
may damage the chain link resulting in a failure which can cause harm to the fixture, property, and/or person(s).
Outlet box
Green screw
Crossbar
Hex nut
Nipple
Canopy
Screwcollar loop
Chain

Summary of content (2 pages)