Service manual

Ice Maker Service Manual
Publication Number: 630460082SER - 9 - © 2004-2014, Cornelius Inc.
TO REPLACE WATER LEVEL SAFETY SWITCH
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1. Shut off main power switch or unplug the Ice Maker from electrical outlet.
2. Unplug Molex connector connecting switch to the electrical box.
3. Remove two screws anchoring the water level safety switch to the bottom of the water level control mounting
bracket.
ICE LEVEL CONTROL
The ice level control assembly is secured to the top of the ice storage container cover. When the switch assembly is
down, due to lack of ice in the ice storage container, an electrical impulse is sent to the compressor to start the ice
making cycle. As ice level increases in the ice storage container, the switch assembly is pushed back. When the ice
storage container is full, it de-actuates the switch which stops the compressor and the ice making cycle.