Service manual

Ice Maker Service Manual
Publication Number: 630460082SER - 3 - © 2004-2014, Cornelius Inc.
GENERAL INFORMATION
SPECIFICATIONS
DESCRIPTION
Models WM600 and CM600 Ice Makers are self-contained wall mount and counter style Units which automatically
make hard compressed-style ice and store it in a sealed hopper for sanitary dispensing.
INSTALLATION INSTRUCTIONS
IMPORTANT: An Ever pure Model 9320 – 42 Systems IV Model DB900 ice maker quality water
treatment unit MUST BE INSTALLED in the water supply line to the Ice Maker. Failure to do so may
result in poor quality ice, low production output, and may cause premature failure of the Ice Maker
evaporator and void the extended evaporator warranty.
This Ice Maker is provided with a stainless–steel evaporator designed to last the life of the product. But,
some of the chemicals in treated and untreated water, specifically chlorine and sulphur (sulphide), have the
ability to attack stainless–steel and cause premature failure. An initial investment in proper water treatment
will pay for itself in increased production, quality, and long life of the product.
REMOVE ICE MAKER FROM CARTON:
1. Keep Unit in the upright position, remove carton and pallet from the Unit and inspect the unit for damage. Upon
inspection of the unit, if any damage is found, file a claim with the carrier immediately.
2. Locate the Startup Card either on the outside of the container or on the plastic liner. Fill in the proper informa-
tion and send one copy to the factory and the other copy to the Distributor. The postage is prepaid.
CABINET REMOVAL
1. Unscrew and remove the front panels for electrical and start–up access.
2. Remove shipping tape from the storage hopper cover and the agitator in storage hopper.
PREPARATION OF INSTALLATION SITE
1. For maximum efficiency and ice output, select a location for your ice maker where it will not be exposed to sun-
light, excessive heat or reflected radiation (preferably in a room with a temperature of 70° F to 80° F). The ice-
maker normally will not function properly in temperatures below 65° F. The area surrounding the ice maker
should be well ventilated. (Consult ???? for proper airflow clearance). WM600 – Two (2) mounting brackets are
supplied for securing the Unit to a wall.
CM600 – Consult Figure 1B and 1C for dimensions for mounting the Unit to the counter. Note that the Unit must be
level for proper operation.
2. The Unit must be sealed to the counter. Locate the desired position for the Unit, then mark the outline dimen-
sions on the counter.
Model WM (Wall Model) 600 and CM (Counter Model) 600
Compressor 3/4 H.P. (R404 Refrigerant)
Voltage 115 VAC, 60 Hz, Single Phase
Current Draw 16 Amps
Circuit Breaker or Fuse Size 20 Amp Maximum Time Delay