Service manual

Ice Maker Service Manual
Publication Number: 630460082SER - 5 - © 2004-2014, Cornelius Inc.
INITIAL START UP, CHECKS AND ADJUSTMENT INSTRUCTIONS
NOTE: Do not start the Unit before completing the previous Installation steps.
Turn on the water supply and main power switch (located on top of the electrical box).
NOTE: If the Unit will not start, be sure the water reservoir is full. The low water safety control must
be properly adjusted to start and shut down the Unit. If the water level drops below the bottom of
the reservoir, the Unit must shut down. Adjustment is made by moving the magnet up or down.
Figure 1. Float Adjustment
Water Level Control Adjustment – If necessary, adjust the float by bending the float arm up or down as
needed. Push the float assembly down until the Unit stops running. Release the float and the Unit will
restart. Keep water in the reservoir at the level line while the Unit is in operation (See Figure 1).
Low Water Safety Control – Adjust the magnet by bending the magnet arm as shown in Figure 1 to shut down the
Unit if the water level drops below the line on the side of the reservoir.
Bin Control – Remove four clips from top of the bin cover and lift cover so the bin control switch can be manually lifted
until the Unit shuts down. Release the plate and unit will restart
Dispense Switch and Mechanism – By depressing the dispense switch, the dispense mechanism door on the
storage bin will open, and the agitator will rotate counterclockwise.
NOTE: If any of these checks or adjustments cannot be achieved, refer to Troubleshooting Section
of this manual or call our Technical Support Center for assistance.