IMI CORNELIUS REMCOR INC g 500 REGENCY DRIVE g GLENDALE HEIGHTS, IL 60139--2268 Telephone (800) 551--4423 Facsimile (800) 519--4423 Installation Manual ICE DISPENSER D45 and D90 Part No. 91561 August, 1995 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment Ó IMI CORNELIUS INC; 1992--95 PRINTED IN U.S.
TABLE OF CONTENTS Page SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CLEANING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY PRECAUTIONS ALWAYS: Disconnect power to the dispenser before servicing or cleaning. NEVER: Place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when dispenser is energized! This ice dispenser has been specifically designed to provide protection against personal injury and eliminates contamination of ice.
INSTALLATION INSTRUCTIONS 1. Locate the dispenser indoors on a level counter top. Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit. 2. Connect the 3/4?IPS (or equal) drain line to the 3/4?threaded drain connections at the lower rear of the unit. This line must pitch downward to an open drain and must contain no traps, or improper drainage will result. 3. Clean the hopper interior. (See Cleaning Instructions on page 3.) 4.
OPERATING INSTRUCTIONS Fill the hopper with ice and replace the lid. Pushing the dispenser lever will cause ice to flow from the ice chute. Ice flow will continue until the lever is released. If ice does not dispense, see the TROUBLESHOOTING GUIDE to find the cause. NOTE: Use caution to avoid spilling ice when filling dispenser. Immediately clean up any spilled ice from filling or operating the unit. To prevent contamination of ice, the lid must be installed on the unit at all times.
TROUBLESHOOTING GUIDE Should your unit fail to operate properly, check that there is power to the unit and that the hopper contains ice. If the unit still does not dispense, check the following chart under the appropriate symptoms to aid in locating the defect. Trouble BLOWN FUSE OR CIRCUIT BREAKER. GATE DOES NOT OPEN. AGITATOR DOES NOT TURN. GATE DOES NOT OPEN OR IS SLUGGISH. AGITATOR TURNS. GATE OPENS. AGITATOR DOES NOT TURN. ICE DISPENSES CONTINUOUSLY. SLUSHY ICE. WATER IN HOPPER.
1 5/8-IN. 15 7/8-IN. 12 5/8-IN. 1 5/8-IN. D45 18 9/16-IN. OUTLINE OF UNIT 21 25/32-IN. 3/4-DIA. (4) 22-IN. 1 1/8-IN. 19 3/4-IN. 1 1/8-IN. D90 16 1/4-IN. OUTLINE OF UNIT 27 23/32-IN. 3/4-DIA. (4) FIGURE 1.
ICE LEVEL SIGNAL L N GROUND GRN OPTION T’STAT LIGHT 1 LIGHTED DISPLAY 2 OPTION WHT BALLAST BLK LIGHT BLK WHT STARTER WHT GATE SOLENOID 1 1/4 AMP TIME DELAY FUSE RED WHT TERMINAL BOARD RED AGITATOR MOTOR PORTION TIMER SW OR RED TD DISPENSE CONTROL OPTION TO TERMINAL RED PORTION BLK DISPENSE SWITCH WHT CAPACITOR D90 ONLY SWITCH RED BLK BOARD SERVICE INFORMATION ELECTRIC SHOCK HAZARD. DISCONNECT DANGER! POWER BEFORE SERVICING UNIT.
1 2 22 4 3 5 4 22 6 19 18 22 20 21 8 16 15 14 11 10 17 19 13 9 12 7 FIGURE 3. SOLENOID ASSEMBLY -- EXPLODED VIEW AND PARTS LIST Index No. Part No. Qty. Name 1 21493 1 2# 31551 1 Solenoid Mounting Plate Solenoid Service Kit 3 70171 2 8--32 x 3/8 Phil Tr HD Screw 4 70121 2 No.
CUP ACTIVATED 7 8 3 2 10 PUSH LEVER 7 8 4 5 FIGURE 4.
PARTS LIST Item Description Part No. D45 Part No.
IMI CORNELIUS INC. ONE CORNELIUS PLACE ANOKA, MN. 55303--6234 TELEPHONE (800) 238--3600 FACSIMILE (612) 422--3232 WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius product, in your country, please write, Fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number and the date of purchase.
CORPORATE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139