Use and Care Manual

10 11
Install a manual shut-off valve in the gas line in an easily accessible location
outside the cooktop. Be sure you know how and where to shut off the gas
supply to the cooktop. Install the electrical outlet 12” below the countertop.
Electrical supply:
This cooktop features pilotless electric ignition for energy savings and reliabil-
ity. It operates on a 120 volt, 60 Hz power supply. A separate circuit, protected
by a 15 amp time delay fuse or circuit breaker is required.
·A properly-grounded 3-prong receptacle should be located within reach of
the cooktops four-foot power cord.
(Please read carefully)
FOR PERSON SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
- The power cord of this appliance is equipped with a three-prong (ground-
ing) plug which mates with a standard three-prong grounding wall recep-
tacle to minimize the possibility of electric shock hazard from this appliance.
- The customer should have the wall receptacle and circuit checked by a
qualified electrician to make sure the receptacle is properly grounded and
has correct polarity.
- Where a standard two-prong wall receptacle is encountered, it is the per-
sonal responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
Do Not, Under Any Circumstances, Cut Or Remove The Third (Ground)
Prong From The Power Cord.
Do not use an extension cord.
IMPORTANT
Grounding type
wall receptacle
Do not, under any
circumstances, cut,
remove, or bypass
the grounding
prong.
Power supply cord with
3-prong grounding plug.
POWER SUPPLY LOCATIONS
Gas supply: These cooktops are shipped from the factory set for either natu-
ral gas or LP gas. Check to be sure you have the correct cooktop for the type
of gas being used.
The pressure regulator must be connected in series with the manifold of
the cooktop and must remain in series with the supply line regardless of
type of gas being used.
The natural gas model is designed to operate at 5” water column pres-
sure. A regulator is required at the natural gas source to provide a mini-
mum of 6 water column to the cooktop regulator
The liquid propane model is designed to operate at 10 water column
pressure. A regulator is required at the LP source to provide a minimum of
11” water column to the cooktop regulator. For ease of installation, and if
local codes permit, the gas supply line into the cooktop should be 1/2or
3/4 ID flexible metal appliance connector, three to five feet long.
NOTE: Purchase new flexible line. DO NOT USE OLD, PREVIOUSLY USED FLEXIBLE LINE
The gas inlet is located on the bottom of the burner
box at the rear and center.
Make gas connection through rear wall, or on cabinet floor at rear, as
illustrated.
1- Install the house gas supply at least 1” from the back wall.
2- Locate the electrical outlet 12” below the countertop.