Owner Manual

27 28
Isolate the range from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 psi (3.5 kPa or 14" water column).
ASSEMBLY OF THE BURNERS
The electrode of the electronic ignition system is positioned above the surface of the burner base. Do
not remove a burner cap or touch the electrode of a burner while another is turned on. Damage or
electrical shock may occur.
1. Place burner heads over the burner base.
Make sure the hole in the burner head is
properly aligned with the electrode in the
burner base. (See Figure 13)
2. Place the burner caps on the burner heads.
Make sure that the burner caps are
properly seated on the burner head. (See
Figure 14)
3. Operation of the electric igniters should be
tested after the range and supply line have
been carefully checked for leaks and the
range has been connected to the electrical
power. To check igniters, push and turn a
sounds), but only the burner turned to LITE
will light.
Figure 13
Figure 14
LIQUEFIED PETROLEUM (PROPANE)
GAS CONVERSION
Failure to make the appropriate conversion can result in serious personal injury and property
damage.
The conversion must be performed by a qualified service technician in accordance with
the kit instructions and all local codes and requirements. Failure to follow instructions could
result in serious injury or property damage. The qualified agency performing this work
assumes responsibility for the conversion.
This appliance can be used with Natural Gas or LP/Propane Gas. It is shipped from the factory
for use with Natural Gas. A kit for converting to LP gas (Not Included) can be purchased from
http://www.cosmoappliances.com. The kit is marked "Cosmo LP Conversion Kit (Your model
number)". If you have trouble locating the correct kit, please contact us.
When the range is converted for Liquid Petroleum (LP) Gas, the LP gas supply is required to provide
a minimum of 10 to a maximum of 14” water column to the range regulator.
A. ADJUST THE REGULATOR
Disconnect all electrical power at the main circuit breaker or fuse box.
Shut off the gas supply to the appliance by closing the manual shut-off valve.
Adjust the pressure regulator by doing the following: