Owner Manual
55 56
COOLING FAN RUNS DURING BAKING AND BROILING
■ It is normal for the fan to automatically run while the oven is in use and for some time after to
cool.
OVEN TEMPERATURE TOO HIGH OR TOO LOW
■ Was the oven preheated?
See “Cooking Instructions” section.
■ Are the racks positioned properly?
See “Cooking Instructions” section.
■ Is there proper air circulation around bakeware?
See “Cooking Instructions” section.
■ Is the batter evenly distributed in the pan?
Check that batter is level in the pan.
■ Is the proper length of time being used?
Adjust cooking time.
■ Has the oven door been opened while cooking?
Oven peeking releases oven heat and can result in longer cooking times.
■ Are baked items too brown on the bottom?
Move rack to higher position in the oven.
■ Are pie crust edges browning early?
Use aluminum foil to cover the edge of the crust and/or reduce baking temperature.
NO SPARK WHEN LIGHTING BURNER
■ Electrical supply - The electrical wires or the plug are not connected well.
Connect with electrical power again. If the problem continues, contact a qualified technician.
■ Burner - The burner is not installed correctly.
Install the burner again. See “Placement of Burners and Caps” section.
■ Spark pin - Ignition electrode and the hole are not placed well.
Install the burner again. See “Placement of Burners and Caps” section.
THE FIRE GOES OUT ONCE RELEASING THE KNOB
■ Safety valve - Knob not pressed down long enough.
Press and turn the knob again and keep 3 to 5 seconds after the burner has been lit.
BURNER WON’T IGNITE OR BURNS UNEVENLY
■ Gas valve - The valve is not open.
Make sure the valve is completely open.
■ Gas pipe - There may be air in the gas pipe.
Ignite repeatedly until flame catches.
■ Burner cap
− The burner cap is not placed correctly.
o Replace the burner cap.
− Some holes in the lid are stocked.
o Clean the holes of the lid.
■ Spark pin - The spark pin is wet or contaminated by the food.
Clean and dry the spark pin..
■ Gas connecting pipes - The gas connecting pipes are stocked or squashed.
Contact a qualified technician. Adjust or change the connecting pipes.
THE FLAME GOES OUT DURING OPERATION
■ Thermocouple
− The safety device is contaminated.
o Clean the thermocouple.
− The flame is so little that it can’t touch the thermocouple
o Adjust the flame a little bigger. See the “Proper Burner Adjustments” section.
STRANGE SMELL
■ Gas leaking -
Contact a qualified technician
− The gas supply pipe is old and broken.
o The main burner is not lit.
− Change the gas supply pipe.
o Ignite again after there is no strange smell.