Installation Guide
Liquefied Petroleum (Propane) Gas
Conversion
Failure to make the appropriate conversion can result in serious personal injury and property
damage.
The conversion must be performed by a qualified service technician in accordance with
the kit instructions and all local codes and requirements. Failure to follow instructions could
result in serious injury or property damage. The qualified agency performing this work
assumes responsibility for the conversion.
This appliance can be used with Natural Gas or LP/Propane Gas. It is shipped from the factory for
use with Natural Gas. A kit for converting to LP gas is supplied with your appliance. The kit is
marked "FOR LP/PROPANE GAS CONVERSION".
When the range is converted for Liquid Petroleum (LP) Gas, the LP gas supply is required to provide
a minimum of 10” to a maximum of 14” water column to the range regulator.
A. ADJUST THE REGULATOR
Disconnect all electrical power at the main circuit breaker or fuse box.
Shut off the gas supply to the appliance by closing the manual shut-off valve.
Adjust the pressure regulator by doing the following:
10