Installation Guide
B. CHANGE BURNER NOZZLES
INSTALLATION TIP: First remove all nozzles and then start replacing them. This will help to prevent
the possibility that some may not be replaced.
1) Remove the burner grates, burner caps and burner heads.
2) Using a 7mm nut driver, remove the burner nozzles.
LIQUID PRETROLEUM (LP) GAS NOZZLES
BURNER POSITION NOZZLE
DIAMETER
MINIMUM
PRESSURE
NORMAL
PRESSURE
MAXIMUM
PRESSURE
RATE
(BTU/H)
Auxiliary Front Right 1 x 0.50 3,412
Semi-Rapid Rear Left & Right 1 x 0.65 6,000
Rapid Front Left 1 x 0.85 10,000
Triple Ring Center 1 x 0.95
17 mbar 20 mbar 25 mbar
12,500
IMPORTANT: Carefully read and observe each nozzle label for correct location.
3) Install the proper nozzles in the exact locations as noted in the illustrations above and the
table below. (See Figures 20, 21 and table above)
4) Replace the burner bases, heads, caps and top grates. Make sure burner caps are properly
seated on the burner head.
Figure 20
AUXILARY BURNER
SEMI-RAPID BURNER
RAPID BURNER
1 NOZZLE EACH
Figure 21
12
65
85
65
50
95
TRIPLE RING BURNER
NOZZLES