Installation Guide

Installation Instructions
Gas Connection
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36
cm) water column.
Examples of a qualified person include: licensed heating personnel, authorized gas company
personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This appliance i
s outfitted from the factory to be used with ONLY one type of gas. This range is to be
connected with gas supply line. The gas connection is a male ½” BSP and is located roughly 2 ¼”
from the right and 22” from the ground. The hose needs to be free of kinks or other deformation that
would inhibit its ability to supply gas to the unit or susceptible to a gas leak. Line should also be free
from contact with a moving part such as a drawer, so that it does not become obstructed or damaged.
INSTALLING THE PRESSURE REGULATOR
• This appliance is set for natural gas and is designed to operate at 5” water column pressure. The
gas supply is required to provide a minimum of 4” to a maximum of 14” water column pressure to the
appliance regulator.
22