Installation Guide

NATURAL GAS NOZZLES
BURNER POSITION NOZZLE
DIAMETER
MINIMUM
PRESSURE
MAXIMUM
PRESSURE
Auxiliary Front Right 1 x 1.10 4” 14”
Semi-Rapid Rear Left & Right 2 x 1.29 4” 14”
Rapid Front Left 1 x 1.45 4” 14”
Triple Ring Center 5 x 0.99 4” 14”
• If the appliance i
s converted for liquid pretroleum (LP) gas, the LP gas supply is required to
provide a minimum of 10” to a maximum of 14” water column to the cooktop regulator.
LIQUID PETROLEUM (LP) GAS NOZZLES
BURNER POSITION NOZZLE
DIAMETER
MINIMUM
PRESSURE
MAXIMUM
PRESSURE
Auxiliary Front Right 1 x 0.70 10” 14”
Semi-Rapid Rear Left & Right 2 x 0.80 10” 14”
Rapid Front Left 1 x 0.89 10” 14”
Triple Ring Center 5 x 0.56 10” 14”
The gas supply line must be equipped with an approved manual shut-off valve. The shut-
off valve must be in an easily accessible location in the same room as the appliance. Do not
block access to the shutoff valve. Be sure you know how and where to shut off the gas
supply to the range.
1) The gas inlet i
s located 6” down from the top of the appliance at the rear on the right side and
2 ½” in from the right hand side of the appliance. Make gas connection through rear wall, or on
cabinet floor at rear. Install the house gas supply at least 1from the back wall.
2) When installing, fit a safety valve at the end of the pipeline. The appliance leaves the factory
tested and set for natural gas. Make sure that the type of gas to be supplied to the appliance is
the same as that shown on the label affixed to the rear of the appliance. (See Figure 12)
3) Make the connection to the gas system using a rigid ½” or ¾” metal pipe and regulation unions, or
with a stainless steel hose complying with the local standard. If metal hoses are used, take care
that they do not come into contact with mobile parts and are not crushed.
4) The gas intake connection of the appliance has a “male thread.” When making the connection,
take care not to apply stresses of any kind to the appliance. Over- tightening may crack the
regulator resulting in a gas leak and possible fire or explosion.
23