Installation Guide

5) Once reg
ulator is in place, open the shutoff valve in the gas supply line. Wait a few minutes for
gas to move through the gas line.
6) After c
onnecting the appliance to the gas supply, make sure all burners knobs are in the OFF
position and check the system for leaks with a manometer. If a manometer is not available, turn
on the gas supply and use a liquid leak detector (or soap and water) at all joints and connections
to check for leaks.
TESTING
FOR LEAKS
Do not use a flame to check for leaks from gas connections. Checking for leaks with a flame may
result in a fire or explosion.
Tighten all connections if necessary to prevent gas leakage in the range or supply line.
Check alignment of control knob valves after connecting the range to the gas supply to be
sure the range manifold pipe has not moved. A misalignment could cause the valve stems to rub on
the control panel, resulting in a gas leak at the valve.
Disconnect this range and its individual manual shutoff valve from the gas supply piping
system during any pressure testing of that system at test pressures
in excess of 1/2 psi (3.5 kPa or
14" water column).
Figure 12
24