Installation Guide

TESTING FL
AME STABILITY
Test 1——Turn t
he knob from “HI” to “LO” quickly. If the upper row of flames goes out at this setting,
increase the flame size and test again.
Test 2——With the burner on “LO”, open and close the cabinet door under the range. If the flame is
extinguished by the air currents created by the door movement, increase the flame height and test
again.
D. FLAME RE-CHECK
After the adjustment is made, turn all burners off. Ignite each burner individually. Observe the flame
at the “HI” position. Rotate the knob to the lowest setting and be sure that the flame size decreases
as the knob is rotated counter-clockwise.
Adjust the hei
ght of top burner flames. The range “low” burner flame should be a steady blue flame
approximately ¼" (0.64 cm) high.
Once the conversion has been completed and has passed testing, fill out the conversion
sticker and include your name, organization and the date conversion is made. Apply the
sticker near the appliance gas inlet opening to alert others in the future that this appliance has
been converted. If converting back to Natural Gas, please remove the sticker so others know
that the appliance is set to use its original gas.
30